.rs
.\" Troff code generated by TPS Convert from ITU Original Files
.\"                 Not Copyright (~c) 1991 
.\"
.\" Assumes tbl, eqn, MS macros, and lots of luck.
.TA 1c 2c 3c 4c 5c 6c 7c 8c
.ds CH
.ds CF
.EQ
delim @@
.EN
.nr LL 40.5P
.nr ll 40.5P
.nr HM 3P
.nr FM 6P
.nr PO 4P
.nr PD 9p
.po 4P

.rs
\v'|.5i'
.LP
\fBMONTAGE:\ \ \ \fR Fin de la Rec. X.316 en t\*\|ete de cette page
.sp 2P
.LP
\v'31P'
\fBRecommandation\ X.137\fR 
.RT
.sp 2P
.ce 1000
\fBAVAILABILITY\ PERFORMANCE\ VALUES\ FOR\ PUBLIC\ DATA\ NETWORKS\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Rec.\ X.137''
.OF '''Fascicle\ VIII.3\ \(em\ Rec.\ X.137	%'
.ce 0
.sp 1P
.ce 1000
\fBWHEN\ PROVIDING\ INTERNATIONAL\ PACKET\(hySWITCHED\ SERVICES\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Melbourne, 1988)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIconsidering\fR 
.sp 9p
.RT
.PP
(a)
that Recommendation X.1 specifies the international user classes of service 
in public data networks; 
.PP
(b)
that Recommendation X.2 specifies the international data transmission services 
and optional user facilities in public data networks; 
.PP
(c)
that Recommendation X.25 specifies the DTE/DCE interface for packet mode 
terminals connected to public data networks by dedicated 
circuit;
.PP
(d)
that Recommendation X.75 specifies the packet\(hyswitched signalling system 
between public data networks providing data transmission 
services;
.PP
(e)
that Recommendation X.323 specifies general arrangements for interworking 
between packet\(hyswitched public data networks; 
.bp
.PP
(f
)
that Recommendation X.96 specifies the
international routing principles and routing plan for public data networks;
.PP
(g)
that Recommendation X.110 specifies the international
routing principles and routing plan for public data networks;
.PP
(h)
that Recommendation X.213 defines the OSI Network Layer  service;
.PP
(i)
that Recommendation X.140 defines general quality of
service parameters for communication via public data networks;
.PP
(j
)
that Recommendation X.134 specifies portion
boundaries and packet layer reference events for defining packet\(hyswitched
service performance parameters;
.PP
(k)
that Recommendation X.135 specifies speed of service
performance values for public data networks when providing international
packet\(hyswitched service;
.PP
(l)
that Recommendation X.136 specifies accuracy and
dependability (including blocking) performance values for public data networks 
when providing international packet\(hyswitched service. 
.sp 1P
.LP
\fIunanimously declares\fR 
.sp 9p
.RT
.PP
(1)
that the availability parameters defined in this Recommendation shall be 
used in the planning and operation of international packet\(hyswitched 
data communication service provided in accordance with Recommendations\ X.25
and\ X.75,
.PP
(2)
that in such service, the performance values specified in this
Recommendation shall be taken as worst\(hycase limits under the conditions
specified herein.
.sp 2P
.LP
\fB1\fR 	\fBIntroduction\fR 
.sp 1P
.RT
.PP
1.1
This Recommendation is the fourth in a series of four CCITT
Recommendations (X.134\(hyX.137) that define performance parameters and 
values for international packet\(hyswitched data communication services. 
Figure\ 1/X.137 
illustrates the scope of these four Recommendations and the relationships 
among them. 
.sp 9p
.RT
.PP
1.2
Recommendation X.134 devides a virtual connection into basic
sections whose boundaries are associated with X.25 and X.75 interfaces; 
defines particular collections of basic sections, called virtual connection 
portions, for which performance values will be specified; and defines a 
set of packet 
layer reference events (PEs) which provide a basis for performance parameter
definition. The basic sections consist of network sections and circuit
sections. They are delimited, in each case, by physical data terminal equipment 
(DTE) or data switching equipment (DSE) interfaces. Two types of virtual 
connection portions are identified: national portions and international
portions. Each PE is defined to occur when a packet crossing a section 
boundary changes the state of the packet layer interface. 
.PP
1.3
For comparability and completeness, packet\(hyswitched network
performance is considered in the context of the 3\ \(mu\ 3 performance matrix
defined in Recommendation\ X.140. Three protocol\(hyindependent data communication 
functions are identified in the matrix: access, user information transfer, 
and disengagement. These general functions correspond to call set\(hyup, 
data (and 
interrupt) transfer, and call clearing in packet\(hyswitched virtual call 
services conforming to the X.25 and X.75\ Recommendations. Each function 
is considered 
with respect to three general performance concerns (or \*Qperformance criteria\*U): 
speed, accuracy, and dependability. These express, respectively, the delay 
or rate, degree or correctness, and degree of certainty with which the 
function is performed. 
.PP
1.4
Recommendation X.135 defines protocol\(hyspecific speed of service
parameters and values associated with each of the three data communication
functions. Recommendation\ X.136 defines protocol\(hyspecific accuracy and
dependability parameters and values associated with each function. The
Recommendation\ X.135 and X.136 parameters are called \*Qprimary parameters\*U 
to 
emphasize their direct derivation from packet layer reference
events.
.bp
.LP
.rs
.sp 43P
.ad r
\fBFigure 1/X.137 p. 1\fR 
.sp 1P
.RT
.ad b
.RT
.PP
1.5
An associated two\(hystate model provides a basis for describing
overall service availability. A specified availability function compares the
values for a subset of the primary parameters with corresponding outage
thresholds to classify the service as \*Qavailable\*U (no service outage) or
\*Qunavailable\*U (service outage) during scheduled service time. This
Recommendation specifies the availability function and defines the availability 
parameters and values that characterize the resulting binary random process. 
.PP
1.6
Two availability parameters are defined in this Recommendation:
service availability and mean time between service outages. Each parameter 
can be applied to any basic section or portion of a virtual connection. 
This 
generality makes the parameters useful in performance allocation and
concatenation.
.bp
.PP
1.7
This Recommendation specifies availability values for national and international 
portions of two types (Table\ 1/X.137). Performance values for 
data terminal equipment are not specified, but the parameters defined in 
this Recommendation may be employed in such specification to assist users 
in 
establishing quantitative relationships between network performance and 
quality of service (see Recommendation\ X.140). 
.ce
\fBH.T. [T1.137]\fR 
.ce
TABLE\ 1/X.137
.ce
\fBVirtual connection portion types for which performance\fR 
.ce
\fB
.ce
values are specified\fR 
.ce
\|\ua\d\u)\d
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(60p) | cw(120p) .
Portion type	Typical characteristics
_
.T&
lw(60p) | lw(120p) .
National A	T{
Terrestrial connection via an access network
section
T}
_
.T&
lw(60p) | lw(120p) .
National B	T{
Connection via an access network section with one satellite circuit;
or via an access network section and one or more transit network
sections
T}
_
.T&
lw(60p) | lw(120p) .
International A	T{
Connection via a direct terrestrial internetwork section 
T}
_
.T&
lw(60p) | lw(120p) .
International B	T{
Connection via two satellite circuits and one transit network section;
or via one satellite circuit and two or more transit network
sections
\ua\d\u)\d
The values specified for type B portions also apply to virtual
connection portions not explicitly identified as type A or type B.
.parag
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau 1/X.137 [T1.137], p. 2\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.sp 3
.PP
1.8
Worst\(hycase values for each of the two availability parameters are specified 
below for each virtual connection portion type identified in 
Table\ 1/X.137. The term \*Qworst case\*U means that these values should be met
during the normal busy hour in the worst\(hyperforming virtual connection 
portion used in providing international packet\(hyswitched service. The 
performance of a virtual connection portion may be better than the worst\(hycase 
values specified in this Recommendation. Design objectives that take into 
account more demanding user applications and network performance and connectivity 
enhancements are for further study. 
.PP
Numerical methods for combining individual portion performance
values to estimate end\(hyto\(hyend performance are also provided in this
Recommendation. DTE to DTE values for two particular hypothetical reference
connections are derived using these methods in Annex\ B.
.sp 2P
.LP
\fB2\fR 	\fBAvailability function\fR 
.sp 1P
.RT
.PP
Eight performance parameters from Recommendations X.135 and X.136 are used 
in computing the availability of a virtual connection: throughput 
capacity (X.135), call set\(hyup failure probability (X.136), call set\(hyup 
error 
probability (X.136), residual error rate (X.136), reset probability (X.136),
reset stimulus probability (X.136), premature disconnect probability (X.136), 
and premature disconnect stimulus probability (X.136). Five particular 
linear combinations of these parameters are called the availability decision 
parameters. Each decision parameter is associated with an outage threshold.
These decision parameters and their outage thresholds are listed in
Table\ 2/X.137.
.bp
.RT
.ce
\fBH.T. [T2.137]\fR 
.ce
TABLE\ 2/X.137
.ce
\fBOutage criteria for the availability decision parameters\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(138p) | cw(72p) .
T{
Availability decision parameters
T}	Outage criteria
_
.T&
lw(138p) | lw(72p) .
T{
Call set\(hyup failure probability (cfp)
Call set\(hyup error probability (cep)
T}	(cfp + cep) > 0.9
_
.T&
lw(138p) | lw(72p) .
Throughput capacity (tc)	tc < 80 bit/s
_
.T&
lw(138p) | lw(72p) .
Residual error rate (rer)	rer > 10\uD\dlF261\u3\d
_
.T&
lw(138p) | lw(72p) .
T{
Reset probability (rp)
Reset stimulus probability (rsp
1, rsp
2)
T}	(rsp 1 + rp + rsp 2 ) > 0.015
_
.T&
lw(138p) | lw(72p) .
T{
Premature disconnect probability (pdp)
Premature disconnect stimulus probability (pdsp
1, pdsp
2
)
T}	T{
(pdsp
1 + pdp + pdsp
2
) > 0.01
\fINote\fR
\ \(em\ These outage criteria are provisional.
.parag
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTable 2/X.137 [T2.137], p.\fR 
.sp 1P
.RT
.ad b
.RT
.PP
Performance is considered independently with respect to each
availability decision parameter. If the value of the parameter is equal 
to or better than the defined outage threshold, performance relative to 
that 
parameter is defined to be acceptable. If the value of the parameter is 
worse than the threshold, performance relative to that parameter is defined 
to be 
unacceptable.
.PP
The packet layer reference events that are used in defining the
decision parameters do not occur if a data link layer at a section boundary 
is unavailable. During a continuous time interval the data link layer of 
a circuit section is defined to be available for packet layer service if 
and only 
if:
.RT
.LP
	1)
	 the link is in the information transfer phase for at least 99% of the 
time interval; and 
.LP
	2)
	all continuous periods when the link is not in the
information transfer phase are less than 1\ second in length; and
.LP
	3)
	all continuous busy (flow\(hycontrolled) conditions are less
than 10\ seconds in length.
.LP
Otherwise the data link layer is considered unavailable for providing packet
layer service.
.PP
The data link layer of a circuit section can be unavailable for
the following reasons:
.LP
	1)
	a nonfunctional physical circuit; or
.LP
	2)
	 a data link layer controller either unable or unwilling to establish 
the information transfer phase; or 
.LP
	3)
	 a data link layer controller either unable or unwilling to clear a busy 
condition. 
.PP
A virtual connection section is defined to be available (or to be in the 
available state) if: 
.LP
	1)
	the performance is acceptable relative to all decision
parameters; and
.LP
	2)
	both data link layers at the boundaries of the section are   available.
.PP
The virtual connection section is defined to be unavailable (or in the 
unavailable state) if: 
.LP
	1)
	the performance of one or more of the five decision
parameters is unacceptable; or
.LP
	2)
	 one or both of the data link layers at the boundaries of the section 
are unavailable due to causes inside the section. (Data link layer 
unavailability due to causes outside the section are excluded, i.e.\ failures 
of data link controllers or physical circuits outside the section in 
question.)
.bp
.PP
The intervals during which a virtual connection section is
unavailable are identified by superimposing the unacceptable performance
periods for all decision parameters as illustrated in Figure\ 2/X.137.
.LP
.rs
.sp 23P
.ad r
\fBFigure 2/X.137, p.\fR 
.sp 1P
.RT
.ad b
.RT
.PP
In order to exclude transient impairments from being considered as periods 
of unavailability, a single test of the availability state must exceed 
5\ minutes. In order to reduce the probability of state transitions during 
a 
test of the current availability state, that test should be less than
20\ minutes. A minimal availability test meeting these restrictions is 
defined in Annex\ B. 
.sp 2P
.LP
\fB3\fR 	\fBAvailability parameters\fR 
.sp 1P
.RT
.PP
This section specifies worst\(hycase values for two availability
parameters: service availability and mean time between service outages.
.RT
.sp 1P
.LP
3.1
	\fBService availability\fR \fIdefinition\fR 
.sp 9p
.RT
.PP
Service availability applies to both virtual call and permanent
virtual circuit services. The service availability for a virtual connection
portion is the long\(hyterm percentage of scheduled service time in which that
section is available.
.PP
\fBScheduled service time for a virtual connection section\fR is the
time during which the network provider has agreed to make that section
available for service. The normal objective would be 24\ hours per day, 
7\ days per week. 
.FS
Other scheduled service times may be specified in some
networks.
.FE
A procedure for estimating the availability of a section is
described in Annex\ A.
.RT
.sp 1P
.LP
3.2
	\fIDefinition of\fR \fBmean time between service outages\fR 
.sp 9p
.RT
.PP
Mean time between service outages (MTBSO) applies to both virtual call 
and permanent virtual circuit services. The mean time between service 
outages for a virtual connection section is the average duration of any
continuous interval during which the virtual connection section is available. 
Consecutive intervals of schedules service time are concatenated. Annex\ 
A 
describes a procedure for estimating the mean time between the service 
outages of a section. 
.bp
.PP
Mean time between service outages as defined in this Recommendation is 
closely related to mean time between failures. 
.RT
.sp 1P
.LP
3.3
	\fIValues\fR 
.sp 9p
.RT
.PP
The conribution from each network portion to overall service
availability and mean time between service outages under the conditions
described in this Recommendation shall not be worse than the values specified 
in Table\ 3/X.137. The mean time between service outage values for national 
portions exclude up to 5% of virtual connections to account for geographical
and climatic extremes.
.RT
.ce
\fBH.T. [T3.137]\fR 
.ce
TABLE\ 3/X.137
.ce
\fBWorst\(hycase service availability and mean time
.ce
\fBbetween service\fR 
.ce
\fBoutage values for virtual connection portions\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(72p) | cw(30p) sw(30p) sw(30p) sw(30p) , ^  | c s | ^ , ^  | c | c | c s 
^  | ^  | ^  | c | c.
Statistic	T{
Virtual connection portion type
T}
		National
	A  	B	International	A  	B
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
Service availability
(percent)
T}	99.5	99	99.5	99
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
Mean time between service outages (hours)
T}	1200	800	1600	800
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
Mean time to service restoral MTTSR\|\ua\d\u)\d (hours)
T}	(6)	(8)	(8)	T{
(8)
\ua\d\u)\d
The parenthetical values given in Table 3/X.137 represent the mean time to service restoral that would result if the service availability and the mean time between service outage values are achieved as stated in the table.
Any improvements in MTBSO should be used to improve service availability and
should not be used to degrade MTTSR.
.parag
\fINote\fR
\ \(em\ All specified values are provisional.
.parag
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTable 3/X.137 [T3.137], p.\fR 
.sp 1P
.RT
.ad b
.RT
.sp 1P
.LP
3.4
	\fIRelated parameters\fR 
.sp 9p
.RT
.PP
Four other parameters are commonly used in describing availability performance. 
These are generally defined as follows: 
.RT
.LP
	\(em
	\fBmean time to service restoral (MTTSR)\fR is the average
duration of unavailable service time intervals.
.LP
	\(em
	\fBfailure rate (\(*l)\fR is the average number of transitions
from the available state to the unavailable state per unit available time.
.LP
	\(em
	 \fBrestoral rate (\(*m)\fR is the average number of transitions from 
the unavailable state to the available state per unit unavailable time. 
.LP
	\(em
	 \fBunavailability (U)\fR is the long\(hyterm ratio of unavailable service 
time to scheduled service time, expressed as a percentage. 
.PP
Under the exponential distribution assumption of failure and
restoration, the mathematical values for any of these parameters may be
estimated from the values for service availability (A) and mean time between
service outages as summarized in Figure\ 3/X.137.
.bp
.LP
.rs
.sp 34P
.ad r
\fBFigure 3/X.137 p. 6\fR 
.sp 1P
.RT
.ad b
.RT
.ce 1000
ANNEXE\ A
.ce 0
.ce 1000
(to Recommendation X.137)
.sp 9p
.RT
.ce 0
.ce 1000
\fBSampling estimation of availability parameters\fR 
.sp 1P
.RT
.ce 0
.LP
A.1
	\fIA\fR 
\fIminimal test for availability\fR 
.sp 1P
.RT
.PP
The definition of availability requires that observed performance for all 
five decision parameters be compared with outage thresholds. A single success 
of the following test is defined to be sufficient for declaring the 
virtual connection section available. A single failure of a section to 
meet any of the six individual decision criteria is defined to be sufficient 
for 
declaring the virtual section unavailable. This test and its decision criteria 
are defined to be the minimum criteria necessary to sample the availability 
of the section. 
.PP
The minimal availability test can be initiated in either direction
across the section by equipment and components outside of the section. 
The test is divided into two phases: access and user information transfer. 
The access 
phase is used in conjunction with switched virtual calls only.
.bp
.RT
.LP
	Phase\ I:
	Attempt N
.FS
The number N of consecutive call set\(hyups depends on the values of the 
outage decision parameter, to provisionally 4, and so for further study. 
.FE
consecutive call set\(hyups across\ A.
.LP
	Phase\ II:
	 (If the test did not fail in Phase\ I) To ensure that the availability 
test does not fail as a result of insufficient data input, 
attempt to maintain a virtual connection across\ A for 5\ minutes. Attempt to
maintain an average throughput significantly greater than 80\ bit/s (e.g.\ at
least 150\ bit/s) during that interval.
.PP
There are six criteria for deciding if the test has failed or
succeeded:
.LP
	1)
	 The test fails in Phase\ I if all four call set\(hyup attempts result 
in either call set\(hyup error or call set\(hyup failure (switched virtual 
calls only).
.LP
	2)
	The test fails in Phase II if the total reset events plus
reset stimuli is five or greater.
.LP
	3)
	The test fails in Phase II if the throughput is less than
80\ bit/s;
.LP
	4)
	The test fails in Phase II if the residual error rate is
greater than 10\uD\dlF261\u3\d.
.LP
	5)
	The test fails in Phase II if the call and subsequent
reestablishments of that call are cleared two or more times due to premature
disconnects and/or premature disconnect stimuli (switched virtual calls only).
.LP
	6)
	 The test fails in Phase I or Phase II if a data link layer at a section 
boundary is unavailable during a 5\(hyminute interval due to causes inside 
of\ A. 
.PP
If the test passes all six decision criteria, the test is
successful and the virtual connection section\ A is considered to be available 
during the test. If any of the decision criteria are failed, the virtual 
connection section\ A is considered to have been unavailable for the duration 
of the test. 
.PP
Because many performance parameters must be supported simultaneously in 
order for\ A to be considered available, during normal operation (without 
a testing procedure like the one described above) it is not possible to 
prove the section is available (e.g.\ it may not be possible to observe 
both access and 
user information transfer simultaneously). Therefore during normal operation, 
if the section is correctly performing the currently requested function, 
the 
section is assumed to be available.
.PP
Service availability and mean time between service outage values can be 
estimated on the basis of this minimal test (availability performance 
samples). Such estimation is more practical than measurement based on
continuous service observation.
.RT
.sp 1P
.LP
A.2
	\fIProcedures for estimating service availability\fR 
.sp 9p
.RT
.PP
A sufficient estimate of the service availability percentage can be computed 
as follows. Based on an \fIa\ priori\fR estimate of the service 
availability, choose a sample size \*Qs\*U, not less than 300. Choose \*Qs\*U 
testing times during scheduled service time and distribute them across 
a long 
measurement period (e.g.\ 6\ months). Because of the expected durations of
service outages, choose no two testing times closer together than 7\ hours 
(this serves to keep the observations uncorrelated). The testing times 
should be 
uniformly distributed across the scheduled service time. At each predetermined 
testing time perform the availability test described above. If the test 
fails, the section is declared unavailable for that sample. Otherwise, 
the section is declared available. The estimate of the service availability 
percentage is the number of times the section was declared available multiplied 
by 100 and 
divided by the total number of samples.
.RT
.sp 1P
.LP
A.3
	\fIProcedures for estimating mean time between service\fR 
\fIoutages\fR 
.sp 9p
.RT
.PP
A sufficient estimate of the mean time between service outage
parameter can be computed by conducting consecutive availability performance
samples and by counting the observed changes from the available state to the
unavailable state.
.PP
Prior to performing any tests, choose\ \fIk\fR disjoint intervals of time 
each not less than 30 minutes nor more than 3\ hours. The total amount 
of time in the \fIk\fR \ intervals should exceed 3\ times the \fIa\ priori\fR 
estimate of mean time between service outages. For the duration of each 
pre\(hydefined interval conduct consecutive availability performance samples. 
The amount of time observed in 
the available state will be added to a cumulative counter called \*QA\*U. The
number of observed transitions from the available state to the unavailable
state will be accumulated in a counter called \*QF\*U.
.FS
Each counter is
initially set to zero.
.FE
.bp
.PP
For each pre\(hydefined interval:
.RT
.LP
	\(em
	 If all of the consecutive availability samples succeed, then add the 
total length of the interval to\ A. Do not change the cumulative value 
of\ F. 
.LP
	\(em
	 If the first availability sample succeeds and any subsequent sample in 
the interval fails, increase\ F by one. Add to\ A the total length of all 
availability samples prior to the first failure. Following the first failed 
availability sample the remaining time in the interval may be discarded 
without testing its availability. 
.LP
	\(em
	 If the first availability sample fails, assume that the state transition 
occurred before the interval began. Add nothing to the count of 
observed availability time,\ A. Add nothing to the cumulative count of 
observed state changes,\ F. The remaining time in the interval may be discarded 
without testing its availability. 
.PP
After the results of every pre\(hydefined interval have been
accumulated, the ratio, A/F, is an estimate of the mean time between service
outages. A statistically more precise estimate can be obtained by increasing
the number of observed intervals,\ \fIk\fR .
.PP
The estimate of mean time between service outages assumes that, if an outage 
begins during an availability performance sample, either this sample or 
the following sample will decide that the section is unavailable. This 
is a 
reasonable assumption since service outages, in contrast to transient failures, 
will last more than 5\ minutes. 
.PP
Discarding the remainder of the interval following a failed
availability sample is both practical and statistically justifiable. The
virtual connection section must return to the available state before any 
more available time can be accumulated and before any more transitions 
to the 
unavailable state can be observed. First, the expected time to restore 
service may be large with respect to the remaining time in the interval. 
It can be 
inappropriate and counterproductive to continue testing a failed or congested 
network section. Second, if transitions to the unavailable state are 
.PP
statistically independent, then discarding the remainder of the interval, 
which may include time in the available state and a proportional number 
of 
transitions
back into the unavailable state, will not bias the result.
.FS
If outages tend to be clustered, discontinuing a test following a transition 
to the unavailable state will tend to overestimate the mean time between 
service outages. If 
outages tend to be negatively clustered, discontinuing a test following a
transition to the unavailable state will tend to underestimate the mean time
between service outages.
.FE
The only consequence of discontinuing the test
is the loss of testing time. To minimize that loss, the test intervals 
should be short with respect to the sum of the expected time to restore 
service and 
the expected time between service outages. Thus each test should be no 
longer than 3\ hours. 
.PP
There are two sources of bias in the estimation procedure described
above. First, if an outage begins during the last availability sample of the
interval, that transition may or may not cause the sample to fail. If it 
does not fail, the state transition is missed and the mean time between 
service 
outages is overestimated. Second, a state transition to the unavailable state
.PP
during the first availability sample of the interval may or may not cause 
that sample to fail. According to the estimation procedure, if the sample 
does fail, the interval will be discarded, the state transition is missed, 
and the mean 
time between service outages is overestimated. These edge effects can be
minimized by increasing the length of each interval, consequently increasing
the number of availability samples, and thus decreasing the effect of the 
first and last sample outcomes as a proportion of the total sampled outcomes. 
A 
minimum recommended interval length is 30\ minutes and size 5\ minute
availability samples.
.PP
Alternatively, both biases can be corrected by replacing the first
instruction above with:
.RT
.LP
	\(em
	 If all of the consecutive availability samples succeed, then add the 
total length of the interval to\ A. Take one additional availability 
sample immediately following the interval. If that sample fails, increase\ 
F by one. If that sample succeeds, do not change\ F. The length of the 
additional 
sample has no effect on\ A.
.PP
This modification identifies any state transitions that occurred during 
the last sample of the interval and eliminates the first source of bias. 
It also counts certain transitions that occurred outside of the interval. 
These transitions are counted with the same probability as the probability 
that the second source of bias inappropriately discards transitions. Thus 
this modified procedure corrects both sources of bias. Using this modification, 
the mean time between service outages can be more accurately estimated. 
.bp
.ce 1000
ANNEX\ B
.ce 0
.ce 1000
(to Recommendation X.137)
.sp 9p
.RT
.ce 0
.ce 1000
\fBRepresentative end\(hyto\(hyend availability performance\fR 
.sp 1P
.RT
.ce 0
.PP
This annex provides two examples to illustrate how end\(hyto\(hyend (DTE 
to DTE) availability performance can be estimated from the individual 
virtual connection portion performance values specified in
Recommendation\ X.137. Two example concatenations of Type\ A and Type\ 
B virtual connection portions are defined. The end\(hyto\(hyend service 
availability and mean time between service outages are calculated for each 
example. Although 
alternative network models and statistical assumptions are possible, the
methods
presented in this annex provide one practical way of estimating the end\(hyto\(hyend 
performance from the performance of the individual network portions. 
.sp 1P
.RT
.sp 1P
.LP
B.1
	\fIDefinition of the example end\(hyto\(hyend connections\fR 
.sp 9p
.RT
.PP
For ease of reference the two example end\(hyto\(hyend (i.e.\ DTE to DTE) 
connections presented in this annex will be referred to as \*QType\ 1\*U 
and 
\*QType\ 2\*U configurations. These hypothetical, but representative,
configurations use the portion boundaries and packet layer reference events
described in Recommendation\ X.134. Table\ 1/X.137 defines the virtual 
connectin portion types. 
.PP
The Type 1 configuration is defined to be:
.RT
.ce
\fBH.T. [T4.137]\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
lw(24p) | lw(108p) | lw(24p) .
		
.T&
cw(24p) | lw(108p) | cw(24p) .
DTE		DTE
.T&
lw(42p) | lw(48p) | lw(42p) .
		
.TE
.nr PS 9
.RT
.ad r
\fBTable [T4.137] p.\fR 
.sp 1P
.RT
.ad b
.RT
.ce
\fBH.T. [T5.137]\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
lw(24p) | lw(108p) | lw(24p) .
		
.T&
cw(24p) | lw(108p) | cw(24p) .
DTE		DTE
.T&
lw(42p) | lw(48p) | lw(42p) .
		
.TE
.nr PS 9
.RT
.ad r
\fBTable [T5.137] p.\fR 
.sp 1P
.RT
.ad b
.RT
.sp 1P
.LP
B.2
	\fIEnd\(hyto\(hyend availability performance for the Type 1 and\fR 
\fIType 2 configuration examples\fR 
.sp 9p
.RT
.PP
End\(hyto\(hyend availability performance values have been calculated for 
the example Type\ 1 and Type\ 2 connection configurations and are reported 
below in Tables\ B\(hy1/X.137 and\ B\(hy2/X.137. These calculations have 
been made by 
applying
the methods described below to the individual network portions that, for
convenience in defining these examples, are characterized by the worst\(hycase
accuracy and dependability performance values specified in
Recommendation\ X.137.
.PP
Assuming that the service availability performance values associated with 
the individual network portions are statistically independent, then the 
end\(hyto\(hyend performance values can be calculated by multiplying the 
percent of time each of the network portions is available. 
.PP
\fIExample\fR : To compute the end\(hyto\(hyend service availability for the
Type\ 1 configuration, refer to Table\ 3/X.137 to obtain the individual 
portion availabilities (National A: percent =\ 99.5; International\ A: 
percent =\ 99.5). The end\(hyto\(hyend availability in percent is then: 
\v'6p'
.RT
.sp 1P
.ce 1000
99.5\|\(mu\|99.5\|\(mu\|99.5\ =\ 98.5
.ce 0
.sp 1P
.LP
.sp 1
.bp
.PP
The end\(hyto\(hyend performance for the mean time between service
outages can be estimated by assuming that the times between service outages 
in each individual network portion are independent and exponentially distributed. 
It follows from these assumptions that the end\(hyto\(hyend mean time between 
service outages performance objective, \fIT\fR , can be calculated using 
the following 
formula:
\v'6p'
.sp 1P
.ce 1000
\fIT\fR = [\fIT\fR\d1\u\uD\dlF261\u1\d + \fIT\fR\d2\u\uD\dlF261\u1\d + 
.\|.\|.\ + \fIT\fR\d\fIi\fR\u\uD\dlF261\u1\d + 
.\|.\|.\ + \fIT\fR\d\fIN\fR\u\uD\dlF261\u1\d]\uD\dlF261\u1\d
.ce 0
.sp 1P
.LP
.sp 1
where \fIT\fR will be in hours if the mean time between service outages 
for each of the \fIN\fR network portions, \fIT\fR\d\fIi\fR\u(i\ =\ 1, 2,\ 
.\|.\|., \fIN\fR ), is expressed in 
hours.
.PP
\fIExample:\fR For the Type 1 configuration the National\ A portion
mean time between service outages is 1200\ hours and the International\ 
A portion is 1600\ hours (refer to Table\ 3/X.137). The end\(hyto\(hyend 
performance objective is then: 
\v'6p'
.sp 1P
.ce 1000
[1200\uD\dlF261\u1\d + 1600\uD\dlF261\u1\d + 1200\uD\dlF261\u1\d]\uD\dlF261\u1\d 
= 436 heures 
.ce 0
.sp 1P
.LP
.sp 1
.ce
\fBH.T. [T6.137]\fR 
.ce
TABLE\ B\(hy1/X.137
.ce
\fBEnd\(hyto\(hyend availability and mean time between service outage\fR 
.ce

.ce
\fB\fBperformance for the type 1 configuration
.ce
\fBexample\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(168p) .
Type 1 configuration
_
.T&
cw(120p) | cw(48p) .
Statistic	End\(hyto\(hyend value
_
.T&
lw(120p) | cw(48p) .
T{
Service availability (percent)
T}	98.5
_
.T&
lw(120p) | cw(48p) .
T{
Mean time between service outages (hours)
T}	436
_
.TE
.nr PS 9
.RT
.ad r
\fBTable B\(hy1/X.137 [T6.137] p.\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.sp 4
.ce
\fBH.T. [T7.137]\fR 
.ce
TABLE\ B\(hy2/X.137
.ce
\fBEnd\(hyto\(hyend availability and mean time between service outage\fR 
.ce

.ce
\fB
.ce
performance for type 2 configuration
.ce
\fBexample\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(168p) .
Type 2 configuration
_
.T&
cw(120p) | cw(48p) .
Statistic	End\(hyto\(hyend value
_
.T&
lw(120p) | cw(48p) .
T{
Service availability (percent)
T}	97.5
_
.T&
lw(120p) | cw(48p) .
T{
Mean time between service outages (hours)
T}	300
_
.TE
.nr PS 9
.RT
.ad r
\fBTable B\(hy2/X.137 [T7.137] p.\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.sp 2P
.LP
\fBRecommendation\ X.140\fR 
.RT
.sp 2P
.ce 1000
\fBGENERAL\ QUALITY\ OF\ SERVICE\ PARAMETERS\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Rec.\ X.140''
.OF '''Fascicle\ VIII.3\ \(em\ Rec.\ X.140	%'
.ce 0
.sp 1P
.ce 1000
\fBFOR\ COMMUNICATION\ VIA\ PUBLIC\ DATA\ NETWORKS\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Malaga\(hyTorremolinos, 1984; amended at Melbourne, 1988)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIconsidering\fR 
.sp 9p
.RT
.PP
(a)
that users of data transmission services need general
parameters which express their quality of service requirements without
reference to any particular service or the means of its provision;
.PP
(b)
that 
providers of data transmission services
need similar general parameters for representing offered services, and for
relating user quality of service requirements to network performance
capabilities;
.PP
(c)
that Recommendations X.130 and X.131 define
protocol\(hyspecific performance parameters and objectives for circuit\(hyswitched 
public data networks;
.PP
(d)
that Recommendation X.134 specifies portion boundaries and packet\(hylayer 
reference events for defining packet\(hyswitched performance 
parameters;
.PP
(e)
that Recommendations X.135, X.136 and\ X.137 define
protocol\(hyspecific performance parameters and values for packet\(hyswitched 
public data networks; 
.PP
(f
)
that Recommendation X.200 defines the Reference
Model of Open Systems Interconnection (OSI) for CCITT applications;
.PP
(g)
that Recommendation X.213 defines the OSI Network
Service;
.PP
(h)
that Recommendation X.300 defines general principles and arrangements for 
interworking among public data networks, and between public 
data networks and other networks,
.sp 1P
.LP
\fIunanimously recommends\fR 
.sp 9p
.RT
.PP
that the general parameters defined below be used in specifying
the end\(hyto\(hyend quality of public data network services as seen from 
the user's point of view. 
.sp 2P
.LP
\fB1\fR 	\fBScope and application\fR 
.sp 1P
.RT
.PP
1.1
This Recommendation defines a set of general quality of
service (QOS) parameters for public data networks (PDNs). The parameters
have two essential characteristics:
.sp 9p
.RT
.LP
	1)
	 they focus on performance \fIeffects\fR \|which are observable at the 
network interfaces, rather than their causes within the 
network; and
.LP
	2)
	 their definitions are based on protocol\(hyindependent events (e.g.\ 
access request) rather than protocol\(hyspecific interface 
events (e.g.\ issuance of an X.21 \fIcall request\fR signal).
.bp
.PP
These characteristics make the parameters independent of
application, network, and service. With proper specialization, they may 
be used to specify or measure the quality of any data communication service, 
irrespective of network internal design or network access protocol. Examples 
of data communication services to which the parameters may be applied are 
circuit\(hyswitched services, packet\(hyswitched services, and leased circuit
services. The parameters are applicable to both connection\(hyoriented and
connectionless services.
.PP
1.2
The general quality of service parameters defined in this
Recommendation are specifically designed to be used in relating the performance 
capabilities of particular network services with user requirements (see 
Figure\ 1/X.140). The network specific performance parameters defined in
other
X\(hyseries Recommendations are focused on specific service interface protocols
(e.g.\ X.21, X.25) and specific network configurations (e.g.\ X.92, X.110). 
They are essential for network design and operation and component performance 
specification, but are not necessarily understandable or relevant to users.
Similarly, performance requirements of users are often focused on particular
applications (e.g.\ electronic funds transfer, text editing) and may not be
directly useful to 
network providers
. An example is the data processing parameter \*Qresponse time\*U. The 
general parameters provide a \*Qcommon language\*U for relating the two. 
They enable users to specify communication requirements without presupposing 
any particular service, network, or protocol, and enable providers to describe 
service performance in terms that are relevant to users, but not specialized 
to any particular application. 
.sp 9p
.RT
.LP
.rs
.sp 32P
.ad r
\fBFigure 1/X.140, p.\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.PP
1.3
The general parameters are principally intended to describe
communication performance at interfaces between public data networks and
customer DTEs. The detailed characteristics of such network\(hyuser interfaces
depend on the type of network service and the user application. The quality
of X.21\(hybased 
circuit\(hyswitching networks
is described in terms of
signals occurring at the physical DTE/DCE interfaces (e.g.\ \fIcall request\fR 
, 
\fIincoming call\fR ). The quality of X.25\(hybased 
packet\(hyswitching networks
is described in terms of corresponding events (or state transitions) occurring 
at the packet layer of\ X.25. Specific relationships between the X.140 
parameters and the 
circuit\(hyswitching and packet\(hyswitching network
performance
parameters defined in the X.130\(hyseries Recommendations are
described in Annexes\ A and\ B, respectively.
.PP
1.4
Many applications of public data networks will conform to the
Reference Model of 
open systems interconnection
for CCITT applications (CCITT Recommendation\ X.200). In that model, QOS 
parameters are defined as 
abstract boundaries between layers. Public data networks provide support for
the OSI network service (Recommendation\ X.213). The 
QOS parameters
defined in the OSI network service reflect those aspects of public data 
network quality of service that are observable and significant to OSI network 
service users. The general relationship between PDN quality of service 
and OSI network service quality is illustrated in Figure\ 2/X.140. Specific 
relationships 
between the X.140 QOS parameters and the network layer QOS parameters are
defined in Annex\ C. Relationships among the general parameters, the
X.130\(hyseries parameters, and the OSI network service performance QOS 
parameters are summarized in Figure\ 3/X.140. 
.LP
.rs
.sp 33P
.ad r
\fBFigure 2/X.140, p.\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.LP
.rs
.sp 33P
.ad r
\fBFigure 3/X.140, p.\fR 
.sp 1P
.RT
.ad b
.RT
.PP
1.5
Because the X.140 parameters are based on protocol\(hyindependent
events, they may also be applied at higher layers in the OSI model.
Application of the X.140 parameters at the OSI end user interfaces is
illustrated in Figure\ 2/X.140. Details of parameter specialization,
relationships to application\(hyspecific parameters, and the mapping of 
end user QOS values into corresponding lower layer values are for further 
study. 
.PP
1.6
A requirement also exists to describe QOS at higher layers
(above the network layer) in non\(hyOSI applications. An example is the 
X.28/X.29 PAD facility. Use of the X.140 parameters to express QOS characteristics 
in 
such applications, and possible relationships to PDN QOS parameters, are 
also for further study. 
.PP
1.7
Some public networks will have the capability to signal QOS
requests and conditions, or to permit users to \*Qnegotiate\*U certain QOS
characteristics of the network. This Recommendation does not describe any
public data network capabilities of this kind, nor does it specify how they
.LP
might be used. The provision and use of such capabilities will be the subject 
of other Recommendations (for example, Recommendations describing how public 
data networks may support the OSI network service). In the case of interworking 
between networks, such capabilities are described in Recommendation\ X.300. 
.PP
1.8
This Recommendation does not specify values for the 
general
QOS parameters
. Values may be specified either by the service user, in
characterizing a particular data communication requirement, or by the service 
provider, in characterizing a particular service offering. Values may be 
measured by either the users or the provider.
.bp
.PP
1.9
To ensure comparability, stated values for the general parameters should 
be accompanied by supplementary information which clearly identifies 
their scope of application and statistical meaning. User delays may be
\*Qfactored out\*U of stated delay and transfer rate values using the method
defined below. The same method can be used to factor out 
provider
delays in cases where an assessment of user performance is desired.
.PP
1.10
Figure 4/X.140 identifies the general QOS parameters defined in
this Recommendation. The parameters are of two types: primary parameters and
availability parameters. The primary parameters describe performance during
periods of normal service operation, in the absence of service outages. The
availability parameters describe the frequency and duration of service
outages.
.ce
\fBH.T. [T1.140]\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
lw(48p) | cw(60p) | cw(60p) | cw(60p) .
Function  Criterion	Speed	Accuracy	Dependability
_
.T&
lw(48p) | lw(60p) | lw(60p) | lw(60p) .
Access	\(bu Access delay	T{
\(bu
Incorrect access probability
T}	T{
\(bu
Access denial probability
T}
_
.T&
lw(48p) | lw(60p) | lw(60p) | lw(60p) .
User information transfer	T{
\(bu
User information transfer delay
\(bu
User information transfer rate
T}	T{
\(bu
User information error probability
\(bu
Extra user information delivery probability
\(bu
User information misdelivery probability
T}	T{
\(bu
User information loss probability
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau [T1.140], p. 14\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.rs
.sp 23P
.ad r
\fBFigure 4/X.140, p. 15\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.PP
1.11
Three protocol\(hyindependent data communication functions are
considered in defining the primary parameters: access, user information
transfer, and disengagement. These general functions correspond to connection 
set\(hyup, data transfer, and connection clearing in connection\(hyoriented 
services. They are also applicable to connectionless services. Each function 
is 
considered with respect to three general performance concerns (or \*Qperformance 
criteria\*U): speed, accuracy, and dependability. These express, respectively, 
the delay or rate, degree of correctness, and degree of certainty with which
the function is performed.
.PP
1.12
An associated two\(hystate model provides a basis for describing
overall service availability. A specified availability function compares the
values for a subset of the primary parameters with corresponding outage
thresholds to classify the service as \*Qavailable\*U (no service outage) or
\*Qunavailable\*U (service outage) during scheduled service time. The availability 
parameters characterize the resulting binary random process. 
.PP
1.13
The remainder of this Recommendation is comprised of three
sections. Section 2 defines the set of user\(hyoriented QOS parameters. 
Section\ 3 describes 
a method of separating delays into user and network components and determining 
\*Qresponsibility\*U for timeout performance failures. Section\ 4 specifies 
supplementary
information which should be provided in conjunction with any statement of
parameter values.
.sp 2P
.LP
\fB2\fR 	\fBParameter definitions\fR 
.sp 1P
.RT
.PP
This section provides definitions for the fourteen user\(hyoriented
QOS parameters.
.RT
.sp 1P
.LP
2.1
	\fBaccess parameters\fR 
.sp 9p
.RT
.PP
Performance of the access function is described by three
parameters: access delay, incorrect access probability, and access denial
probability.
.RT
.sp 1P
.LP
2.1.1
	\fIAccess delay\fR 
.sp 9p
.RT
.PP
Access delay
is the value of elapsed time between an
access request and successful access.
.PP
An access request is any interface signal that notifies the network of 
a user's desire to initiate a data communication session. 
.PP
Elapsed time values are calculated only on access attempts that result 
in successful access. The successful access outcome is indicated in one 
of two ways: 
.RT
.LP
	1)
	by network issuance of a \fIready for data\fR \|or equivalent
signal to the calling user before access timeout, in networks that
provide such a signal; or
.LP
	2)
	by the fact that at least one bit of user information is
input to the system before access timeout, in networks that do not provide a
\fIready for data\fR or equivalent signal. In connection\(hyoriented services, 
there is the additional requirement that the intended called user must 
have been 
contacted and committed to the data communication session during the access
attempt. This requirement distinguishes successful access outcomes from
incorrect access outcomes, as discussed in \(sc\ 2.1.2 below.
.PP
Access delay is divided into user\(hydependent and network\(hydependent 
components. Values for the network\(hydependent components are specified 
in 
network\(hyspecific Recommendations (e.g.\ Recommendation\ X.135).
.sp 1P
.LP
2.1.2
	\fIIncorrect access probability\fR 
.sp 9p
.RT
.PP
Incorrect access probability
is the ratio of total access attempts that result in incorrect access to 
total access attempts in a 
specified sample.
.PP
Incorrect access
is essentially the case of a \*Qwrong number\*U. It occurs when the network 
establishes a physical or virtual circuit connection to a user other than 
the one intended by the call originator, and then does not correct the 
error before the start of user information transfer. Incorrect 
.PP
access can only occur in connection\(hyoriented services, since the network 
does not establish a connection between users in connectionless services. 
Incorrect access is distinguished from 
successful access
(in connection\(hyoriented services) by the fact that the intended called 
user is not contacted and 
committed to the data communication session during the access attempt.
Values for network\(hyspecific parameters corresponding to incorrect access
probability are contained in network\(hyspecific Recommendations
(e.g.\ X.136).
.bp
.RT
.sp 1P
.LP
2.1.3
	\fIAccess denial probability\fR 
.sp 9p
.RT
.PP
Access denial
probability is the ratio of total access
attempts that result in access denial to total access attempts in a specified 
sample. 
.FS
This ratio and all other probability ratios defined in this
Recommendation are actually \fIestimates\fR of the true probability
values.
.FE
.PP
Access denial
(also termed network blocking) can occur in
two ways:
.RT
.LP
	1)
	 the network issues a blocking signal to the originating user during the 
access period (preventing the start of user 
information transfer); or
.LP
	2)
	 the network delays excessively in responding to user actions during the 
access period, with the result that user information 
transfer is not initiated before access timeout. Access denial
is distinguished from service outage by the fact that some
active response (i.e.\ interface signal) is issued by the network
during the access attempt.
.PP
An access attempt can also fail as a result of 
user
blocking
. Such failures are excluded from network performance measurement. User 
blocking is defined as any case where an access attempt fails as 
a result of incorrect performance or non\(hyperformance on the part of a user.
Examples of user blocking include the following:
.LP
	a)
	either the originating or the called user issues a
termination (or blocking) signal to the network during the access period
(preventing the start of the user information transfer); or
.LP
	b)
	the originating or the called user delays excessively in
responding to network actions during the access period, with the result that
user information transfer is not initiated before access timeout. An example 
of the latter is the case where the called user does not answer an incoming 
call.
.PP
Access timeout occurs (i.e. an access attempt is considered to
have failed for performance assessment purposes) whenever the duration of an
individual access attempt exceeds a specified value. A procedure for
distinguishing access denial from user blocking is described in \(sc\ 3.
Values for network\(hyspecific parameters corresponding to access denial
probability are contained in network\(hyspecific Recommendations (e.g.\ X.136).
.PP
\fINote\fR \ \(em\ Delay to access denial is not included as a parameter 
because its effect on the users is considered to be insignificant. 
.RT
.sp 1P
.LP
2.2
	\fBUser information transfer parameters\fR 
.sp 9p
.RT
.PP
Performance of the user information transfer function is described by six 
parameters: user information transfer delay, user information transfer 
rate, user information error probability, extra user information delivery 
probability, user information misdelivery probability, and user information
loss probability.
.RT
.sp 1P
.LP
2.2.1
	\fIUser information transfer delay\fR 
.sp 9p
.RT
.PP
User information transfer delay
is the value of elapsed
time between the start of transfer and successful transfer of a specified 
user information unit (e.g.\ block). 
.PP
The start of user information unit transfer occurs, for any given user 
information unit, when two conditions have been met: 
.RT
.LP
	1)
	all bits in the unit are physically present within the
network facility; and
.LP
	2)
	the network has been authorized to transmit them.
Authorization may either be an explicit user action (e.g.\ typing carriage
return at a buffered CRT terminal) or an implicit part of
inputting the user information itself (e.g.\ typing a single
character at an unbuffered asynchronous terminal).
.PP
The successful transfer outcome is declared (on end of transfer) when an 
information unit is transferred from the source user to the intended 
destination user within the specified transfer timeout period, and the
delivered unit has exactly the form and content intended by the source. The
form or content of an information unit successfully delivered to a destination 
user may differ from that input by the source if desired conversions are 
performed within the network.
.RT
.LP
.sp 1
.bp
.PP
The end of user information unit transfer records the output of user
information units to the destination user in essentially the same way as the
start of transfer records their input at the source. It is defined to occur
when:
.RT
.LP
	a)
	all bits in the unit are physically present within the
destination user facility; and
.LP
	b)
	 the destination user has been notified that the information is available 
for use. The notification may be explicit or 
implicit.
.PP
The user information unit used in defining user information
transfer delay is a contiguous group of user information bits delimited 
at the source user\(hynetwork interface for transfer to a destination user 
as a unit. The specific number of bits in such a unit may be defined by 
the provider in 
specifying an offered service, or by the user in specifying a service
requirement. User information transfer delay is divided into user\(hydependent 
and network\(hydependent components. Values for the network\(hydependent 
components 
are specified in network\(hyspecific Recommendations (e.g.\ X.135).
.sp 1P
.LP
2.2.2
	\fIUser information transfer rate\fR 
.sp 9p
.RT
.PP
User information transfer rate
is the total number of
successfully\(hytransferred user information units in an individual transfer
sample divided by the input/output time for that sample.
.PP
The input/output time for a transfer sample is the larger of the
input time or the output time for that sample (Figure\ 5/X.140). The sample
input time begins when the transfer sample (defined above) begins, and ends
when either:
.RT
.LP
	1)
	 all digits in the sample have been input to the network, and the network 
has been authorized to transmit them; or 
.LP
	2)
	sample input/output timeout occurs.
.PP
The sample output time begins when the first user information
digit in the sample is delivered by the network to the destination user. It
ends when either:
.LP
	\(em
	the last digit of user information in the sample is
delivered to the destination user; or
.LP
	\(em
	sample input/output timeout occurs.
.PP
As noted earlier, either the input or the output of a transfer
sample may be delayed excessively by a user (rejected sample). Such failures
are excluded from network performance measurement. As in the case of user
information transfer denial probability, rejected samples are distinguished
from valid transfer samples using the procedure described in \(sc\ 3.
.PP
\fINote\fR \ \(em\ A \*Qmaximum user information transfer rate\*U which 
excludes the effect of user input/output delays can be calculated using 
the procedure 
described in \(sc\ 3. Values for network\(hyspecific parameters corresponding 
to user information transfer rate are contained in network\(hyspecific 
Recommendations (e.g., X.135).
.RT
.sp 1P
.LP
2.2.3
	\fIUser information error probability\fR 
.sp 9p
.RT
.PP
User information error probability
is the ratio of total incorrect user information units to total successfully 
transferred user 
information units \fIplus\fR incorrect user information units in a specified
sample.
.PP
A transferred user information unit is defined to be an incorrect user 
information unit when the value of one or more digits in the unit is in 
error, or when some, but not all, digits in the unit are lost digits or 
extra digits (i.e.\ digits that were not present in the original signal). 
.PP
Bit error ratio
is a limiting case of user information error probability in which the user 
information unit length, on which the error 
performance is based, is a single binary digit.
.PP
The 
proportion of errored seconds
is a particular case of user information error probability in which the 
user information unit length is 
defined as one second. The number of digits contained in each user information 
unit in this case is numerically equal to the digit rate per second. This 
parameter is usually expressed in the form of the percentage of its
complement, i.e.\ as a percentage of error\(hyfree seconds (% EFS). A similar
parameter, the percentage of error\(hyfree deciseconds (% EFdS), can be 
defined based on a user information unit length of 100\ ms. 
.PP
Values for network\(hyspecific parameters corresponding to user
information error probability are contained in network\(hyspecific
Recommendations (e.g.\ X.136).
.bp
.RT
.LP
.rs
.sp 33P
.ad r
\fBFigure 5/X.140, p. 16\fR 
.sp 1P
.RT
.ad b
.RT
.sp 1P
.LP
2.2.4
	\fIExtra user information delivery probability\fR 
.sp 9p
.RT
.PP
Extra user information delivery probability
is the ratio of total (unrequested) extra information units to total information 
units 
received by a destination user in a specified sample.
.PP
An information unit received by a particular destination user is
declared to be an 
extra information unit
when none of the bits in the unit were input to the system by the source 
user for delivery to that 
destination. Unless misdelivered user information units are explicitly
identified in a measurement process, they will be counted as extra information 
units. Values for network\(hyspecific parameters corresponding to extra 
user 
information delivery probability are contained in network\(hyspecific
Recommendations (e.g.\ X.136).
.RT
.sp 1P
.LP
2.2.5
	\fIUser information misdelivery probability\fR 
.sp 9p
.RT
.PP
User information misdelivery probability
is the ratio of total misdelivered user information units to total user 
information units 
transferred between a specified source and destination user in a specified
sample.
.bp
.PP
A 
misdelivered user information unit
is a user information
unit transferred from a source user to a particular destination user that 
was actually intended for delivery to a different destination user. It 
is 
.PP
considered inconsequential whether the information is correct or incorrect 
in content. Values for network\(hyspecific parameters corresponding to 
user 
information misdelivery probability may be contained in network\(hyspecific
Recommendations (under study).
.RT
.sp 1P
.LP
2.2.6
	\fIUser information loss probability\fR 
.sp 9p
.RT
.PP
User information loss probability
is the ratio of total
lost user information units to total transmitted user information units in a
specified sample.
.PP
A transmitted user information unit is declared to be a lost user
information unit when none of the bits in the unit are delivered to the
intended destination user within the specified timeout period, and the 
network is responsible. 
.PP
User information may also remain undelivered as a result of user
information refusal \(em i.e.\ non\(hydelivery attributable to excessive 
delay on the part of a user. An example is a destination user's exercise 
of flow control. 
Such outcomes are excluded from network performance measurement.
.PP
Transfer timeout occurs (i.e., a transfer attempt is considered to
have failed for performance assessment purposes) whenever the duration of an
individual transfer period exceeds a specified value. A procedure for
distinguishing user information loss from user information refusal is described 
in \(sc\ 3. Values for network\(hyspecific parameters corresponding to 
user 
information loss probability are contained in network\(hyspecific
Recommendations (e.g.\ X.136).
.RT
.sp 1P
.LP
2.3
	\fBdisengagement parameters\fR 
.sp 9p
.RT
.PP
Performance of the disengagement function is described by two
parameters: disengagement delay and disengagement denial probability.
.RT
.sp 1P
.LP
2.3.1
	\fIDisengagement delay\fR 
.sp 9p
.RT
.PP
Disengagement delay
is the value of elapsed time between the start of a disengagement attempt 
for a particular user and successful 
disengagement of that user.
.PP
The disengagement request notifies the system of a user's desire to
terminate an established data communications session. It is complementary to
the access request in most networks.
.PP
Elapsed time values are calculated only on disengagement attempts that 
result in successful disengagement. The successful disengagement outcome 
is 
indicated in one of two ways:
.RT
.LP
	1)
	 by network issuance of a \fIclear confirmation\fR \|or equivalent signal 
to the requesting user before disengagement timeout, in networks that 
provide such a signal; or
.LP
	2)
	 by the fact that the user is able to initiate a new access before disengagement 
timeout, in networks that do not provide a \fIclear\fR 
\fIconfirmation\fR or equivalent signal.
.PP
Disengagement delays may be defined independently for each
participating user when significantly different values are expected.
Disengagement delays are divided into user\(hydependent and network\(hydependent 
components. Values for the network\(hydependent components are specified in
network\(hyspecific Recommendations (e.g.\ X.135).
.sp 1P
.LP
2.3.2
	\fIDisengagement denial probability\fR 
.sp 9p
.RT
.PP
Disengagement denial probability
is the ratio of total
disengagement attempts that result in disengagement denial to total
disengagement attempts in a specified sample.
.PP
The disengagement denial outcome is indicated in one of two
ways:
.RT
.LP
	1)
	by the absence of a \fIclear confirmation\fR \|or equivalent
signal within the disengagement timeout period (in networks that provide 
such a signal); or 
.LP
	2)
	 by the inability of the user to initiate a new access within the specified 
disengagement timeout period (in networks that 
do not provide a \fIclear confirmation\fR or equivalent signal).
.bp
.PP
In some networks, a 
disengagement attempt
can also fail as a result of user disengagement blocking. User disengagement 
blocking is defined as any case where a disengagement attempt fails as 
a result of 
incorrect performance or non performance on the part of a user. Examples of
user disengagement blocking include the following:
.LP
	1)
	 a user issues a disengagement blocking signal to the network during the 
disengagement period (preventing the termination of a 
connection\(hyoriented data communication session); or
.LP
	2)
	a user delays excessively in responding to network actions
during the disengagement period, with the result that disengagement is not
completed before disengagement timeout. Such failures are excluded from 
network performance measurement. 
.PP
Disengagement timeout occurs (i.e. a disengagement attempt is
considered to have failed for performance assessment purposes) whenever the
duration of an individual disengagement attempt exceeds a specified value. A
procedure for distinguishing disengagement denial from user disengagement
blocking is described in \(sc\ 3. Values for network\(hyspecific parameters
corresponding to disengagement denial probability are contained in
network\(hyspecific Recommendations (e.g.\ X.136).
.sp 1P
.LP
2.4
	\fBAvailability parameters\fR 
.sp 9p
.RT
.PP
Three parameters are defined to describe overall service
availability: service availability, user information transfer denial
probability, and service outage duration.
.RT
.sp 1P
.LP
2.4.1
	\fIService availability\fR 
.sp 9p
.RT
.PP
Service availability
is the ratio of the aggregate time
during which satisfactory or tolerable service is, or could be, provided to
the total observation period.
.PP
In practice, the observation period may consist of several
non\(hycontiguous smaller time intervals. The time during which satisfactory or
tolerable service is available includes all time that is not within the 
service outage duration as defined above. The criteria by which the service 
is judged to be unacceptable are for further study. Such study will embrace 
consideration of the parameters, including call\(hyrelated events, that 
are relevant, and 
consideration of the observation period(s) and performance thresholds for
unacceptability. Values for the network\(hyspecific parameter(s) corresponding 
to service availability are contained in network\(hyspecific Recommendations 
(e.g.\ X.137).
.RT
.sp 1P
.LP
2.4.2
	\fIUser information transfer denial probability\fR 
.sp 9p
.RT
.PP
User information transfer denial probability
is the ratio of total transfer denials to total transfer samples during 
a specified 
observation period.
.PP
A 
transfer sample
is a discrete observation of network
performance in transferring user information between a specified source and
destination user. A transfer sample begins on input of a selected user
information digit at the source user interface, and continues until the
outcomes of a given number of transfer attempts have been determined.
.PP
A transfer denial is a transfer sample in which the observed
performance is worse than a specified minimum acceptable level. Transfer
denials are identified by comparing the measured values for four supported
quality of service parameters with specified transfer denial thresholds. The
four supported parameters are user information error probability, user
information loss probability, extra user information delivery probability, 
and user information transfer rate. Transfer denial includes cases where 
the 
network unilaterally terminates user data transmission (e.g.\ reset or 
clearing due to network congestion). 
.PP
A transfer sample may also indicate performance worse than the minimum 
acceptable level if: 
.RT
.LP
	1)
	the source or destination user intentionally disengages
during the sample transfer period; or
.LP
	2)
	 a user delays excessively in inputting or accepting the sample data (e.g.,\ 
through exercise of flow control). Such failures (called rejected samples) 
are excluded from network performance measurement. 
.bp
.PP
A transfer sample input/output timeout occurs (i.e., a transfer
sample is considered to have failed for performance assessment purposes)
whenever the duration of an individual sample input or output period exceeds 
a specified value. A procedure for distinguishing a transfer denial from 
a 
rejected sample is described in \(sc\ 3. Values for network\(hyspecific 
parameters 
corresponding to user information transfer denial probability are
contained in network\(hyspecific Recommendations (e.g.\ X.137).
.sp 1P
.LP
2.4.3
	\fIService outage duration\fR 
.sp 9p
.RT
.PP
Service outage duration
is the duration of any continuous period of time for which satisfactory 
or tolerable service is not available. It is recognized that the determination 
of an outage condition requires a finite observation period. 
.PP
A 
service outage
includes any period during which the user is unable or would be unable 
to elicit any response from the network; i.e.\ the 
network is \*Qdead\*U. It also includes any period during which the service
provided by the network is unacceptable because of, for example, poor error
performance or throughput. The criteria by which the service is judged to be
unacceptable are for further study. Such study will embrace consideration of
the parameters, including call\(hyrelated events, that are relevant, and
consideration of the observation period(s) and performance thresholds for
unacceptability. Values for the network\(hyspecific parameter(s) related to
service outage duration are contained in network\(hyspecific Recommendations
(e.g.\ X.137).
.RT
.sp 2P
.LP
\fB3\fR 	\fBDistinguishing 
\fBnetwork and user components of\fR 
\fBperformance\fR 
.sp 1P
.RT
.PP
This paragraph describes a method of separating delays into network and 
user components and determining \*Qresponsibility\*U for timeout performance 
failures. This is accomplished by dividing selected performance periods into
alternating \*Qresponsibility intervals\*U of two types:
.RT
.LP
	1)
	 intervals in which the network is responsible for creating the next event 
in a sequence of interface events leading to the 
accomplishment of a specified data communication function
(e.g.,\ access);
.LP
	2)
	intervals in which a user is responsible for creating the
next event in such a sequence.
.PP
A simple illustration of this concept is provided in Figure\ 6/X.140. The 
four interface events in a typical connection establishment sequence divide 
the connection establishment period into three 
responsibility
intervals
: two network\(hydependent intervals surrounding one user\(hydependent 
interval. User responsibility intervals must normally be \*Qfactored out\*U 
in 
specifying network performance objectives, since their durations are not 
under network control. 
.PP
Figure 7/X.140 illustrates the responsibility transfer
concept in more detail. Two general types of responsibility transfer events 
are identified and are defined below. Both are defined with respect to 
particular data communication functions and associated performance periods, 
which are 
defined in \(sc\ 3.3.
.sp 1P
.LP
3.1
	\fINetwork\(hyuser responsibility transfer\fR 
.sp 9p
.RT
.PP
A network\(hyuser responsibility transfer occurs upon issuance of any interface 
signal that: 
.RT
.LP
	1)
	initiates user activity needed to accomplish a specified
function;
.LP
	2)
	solicits a subsequent user response indicating that the
required activity has been completed; and
.LP
	3)
	suspends network activity on the function pending the
expected response. Examples are network issuance of an \fIincoming\fR 
\fIcall\fR signal (in Recommendation\ X.21) or packet (in
Recommendation\ X.25) to a called user.
.sp 1P
.LP
3.2
	\fIUser\(hynetwork responsibility transfer\fR 
.sp 9p
.RT
.PP
A user\(hynetwork responsibility transfer occurs on issuance of any
interface signal that:
.RT
.LP
	1)
	initiates network activity needed to accomplish a specified  function;
.LP
	2)
	 solicits a subsequent network response indicating that the required activity 
has been completed; and 
.LP
	3)
	 suspends user activity on the function pending the expected response. 
Examples are user issuance of \fIcall request\fR and \fIcall\fR 
\fIaccepted\fR signals and packets in Recommendations\ X.21 and\ X.25,
respectively.
.bp
.LP
.rs
.sp 47P
.ad r
\fBFigure 6/X.140, p. 17\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.LP
.rs
.sp 28P
.ad r
\fBFigure 7/X.140, p. 18\fR 
.sp 1P
.RT
.ad b
.RT
.sp 1P
.LP
3.3
	\fIUse of the responsibility transfer events\fR 
.sp 9p
.RT
.PP
The 
responsibility transfer events
may be used in defining user and network responsibility intervals within 
four specific performance 
periods:
.RT
.LP
	1)
	the period between the beginning and the end of an access
attempt;
.LP
	2)
	the period between the beginning and the end of a block
transfer attempt;
.LP
	3)
	the period between the beginning and the end of a
disengagement attempt (for a specified user);
.LP
	4)
	the period delimiting the larger of the input time or the
output time for an individual transfer sample (as discussed in
\(sc\ 2.2.2).
.PP
Defining user and network responsibility intervals within the
access, block transfer, and disengagement performance periods enables the
specification of separate network and user values for access delay, user
information transfer delay, and disengagement delay.
.PP
Separation of the above performance periods into user and network
components also provides a method of establishing \*Qresponsibility\*U 
for timeout performance failures i.e.\ whether the user or the network 
should be charged 
with the failure when a performance trial is not completed within the
established timeout period (and no blocking signals are issued). This decision 
is made by comparing the user performance time for the trial that failed 
with a specified maximum user performance time. If the observed user performance 
time exceeds the specified maximum, the failure is attributed to the user; 
otherwise, the failure is attributed to the network. This procedure is 
used in distinguishing access denial from user blocking (\(sc\ 2.1.3); 
user information 
loss from user information refusal (\(sc\ 2.2.6); and disengagement denial from
user disengagement blocking (\(sc\ 2.3.2). It is also used in distinguishing 
the 
transfer denial and rejected sample outcomes in defining user information
transfer denial probability (\(sc\ 2.4.2) and user information transfer rate
(\(sc\ 2.2.2).
.bp
.RT
.sp 2P
.LP
\fB4\fR 	\fBSupplementary information\fR 
.sp 1P
.RT
.PP
This section specifies supplementary information which should be
provided in conjunction with any statement of values for the general QOS
parameters. The specified information is of two types:
.RT
.LP
	1)
	information which identifies the intended scope of
application of the parameter values;
.LP
	2)
	information which identifies the particular statistical
meaning each value expresses.
.PP
Significant differences between user requirement specifications, provider 
service specifications and measurement reports are noted. 
.sp 1P
.LP
4.1
	\fIScope of application\fR 
.sp 9p
.RT
.PP
The intended scope of application of stated QOS values should be
defined by specifying the following interface and usage
characteristics:
.RT
.LP
	1)
	user\(hynetwork interfaces to which the values apply;
.LP
	2)
	interface event sequences (e.g., call request, incoming
call, call accepted, call connected,\ etc.) by which the specified data
communication service is provided in a typical instance;
.LP
	3)
	service refusal actions allowed by the user/network
interface protocol (e.g.\ network clearing in response to a user
call request);
.LP
	4)
	population of users (or communication instances, such as
calls) to which the values apply;
.LP
	5)
	operating conditions (or range of conditions) under which
the values may be expected to hold.
.PP
Particular characteristics may be specified generally or more
precisely, depending on the type of specification. User requirement
specifications define a service need (and any constraints imposed by the 
user application) without reference to a particular service offering. User\(hynetwork 
interfaces and interactions should be defined generally in such specifications, 
with particular mechanical, electrical, or procedural characteristics 
identified only where necessary. The population of users and any
user\(hycontrolled operating conditions (e.g.\ service time interval, offered
traffic) should be defined explicitly. User delays, user information unit
lengths, user input/output rates and the selection of user facilities such 
as abbreviated address calling should also be explicitly defined. 
.PP
Provider service specifications describe the quality of a particular offered 
service, often without references to any particular user application. The 
user\(hynetwork interfaces and interactions are normally defined explicitly 
in such specifications (e.g.\ by reference to an interface specification 
such as 
Recommendations\ X.21 or\ X.25). The user (or call) population and the 
operating conditions may be defined more generally, since they refer to 
potential rather than actual usage. 
.PP
Measurement reports summarize the actual performance of a network
service. Both interface and usage conditions should be specified in detail 
in such reports to ensure comparability. Details which should be specified 
include:
.RT
.LP
	1)
	the particular user\(hynetwork interfaces instrumented;
.LP
	2)
	 the exact user\(hynetwork interaction sequence observed during the measurements, 
and the performance significance assigned to each 
interface event;
.LP
	3)
	the sampling plan used to select the measurement points,
times, and conditions; and
.LP
	4)
	the values or ranges of relevant operating conditions.
Confidence limits and levels associated with each measured
value should also be stated.
.LP
.sp 1P
.LP
4.2
	\fIStatistical meaning\fR 
.sp 9p
.RT
.PP
In order to clearly define the statistical meaning of a stated QOS parameter 
value, it is necessary to: 
.RT
.LP
	1)
	identify the particular distribution characteristic the
parameter represents; and
.LP
	2)
	specify values for any variables which may influence the
parameter definition.
.PP
Any generally accepted statistical measure may be used in stating values 
for the general QOS parameters. \*QMean\*U and \*Q95 percentile\*U values 
are 
specified for the protocol\(hyspecific performance parameters in the X.130\(hyseries 
Recommendations. 
.bp
.PP
The principal variables which may influence the definitions of the
general QOS parameters are listed below:
.RT
.LP
	1)
	\fIperformance timeouts\fR 
.LP
	\(em
	access
.LP
	\(em
	disengagement
.LP
	\(em
	transfer
.LP
	\(em
	sample input/output
.LP
	2)
	\fImaximum user performance times\fR 
.LP
	\(em
	access
.LP
	\(em
	disengagement
.LP
	\(em
	transfer
.LP
	\(em
	sample input/output
.LP
	3)
	\fItransfer denial criteria\fR 
.LP
	\(em
	transfer sample size
.LP
	\(em
	user information error probability threshold
.LP
	\(em
	user information loss probability threshold
.LP
	\(em
	extra user information delivery probability threshold
.LP
	\(em
	user information transfer rate threshold
.LP
	4)
	\fIservice outage criteria\fR (for further study)
.LP
	\(em
	observation period(s)
.LP
	\(em
	defining events
.LP
	\(em
	supported parameters
.LP
	\(em
	unacceptable performance thresholds.
.PP
The performance timeouts establish upper bounds on the associated delay 
distributions. The maximum user performance times provide a basis for 
identifying and eliminating user\(hycaused failures. The transfer denial and
service outage criteria distinguish \*Qunacceptable\*U performance periods from
periods of \*Qsatisfactory or tolerable\*U service.
.PP
Specifications should also indicate whether stated values are \*Qtarget\*U 
or \*Qminimum acceptable\*U values. 
\v'6p'
.RT
.ce 1000
ANNEX\ A
.ce 0
.ce 1000
(to Recommendation X.140)
.sp 9p
.RT
.ce 0
.ce 1000
\fBRelationships between the general QOS parameters and the\fR 
.sp 1P
.RT
.ce 0
.ce 1000
\fBcircuit\(hyswitched service performance parameters\fR 
.ce 0
.PP
This annex describes relationships between the general QOS
parameters defined in Recommendation\ X.140 and the X.21\(hybased,
circuit\(hyswitched service performance parameters for which limits are 
specified in Recommendations X.130 and\ X.131. It illustrates one 
application of the general
parameters and provides a framework for relating user QOS needs with the
performance capabilities of circuit switching PDNs. Such relationships 
may be defined either to allocate a user requirement among network elements, 
in cases where the network performance values are selectable, or to derive 
resultant QOS values from network performance values, in cases where the 
latter are fixed. 
.sp 1P
.RT
.PP
In the example presented here, it is assumed that quality is to be specified 
at a pair of DTE/DCE physical interfaces conforming to 
Recommendation\ X.21. The call set\(hyup and clearing sequences presented are
derived from Annex\ B of that Recommendation.
.PP
Table A\(hy1/X.140 lists the general parameters and the circuit\(hyswitched 
parameters in the rows and columns of a matrix and indicates qualitative 
relationships between them. Specific network performance parameters are 
listed for call processing delays (Recommendation\ X.130) and call blocking 
(Recommendation\ X.131).
.bp
.PP
Within the delay and blocking categories, a mark at a particular
row/column intersection indicates that the corresponding parameters are
interdependent and should be considered jointly in service performance
specification. Each general parameter is influenced by a corresponding
circuit\(hyswitched parameter, and may influence its value if the latter is
.PP
selectable. Detailed relationships between the general parameters and the
corresponding X.130\ delay and X.131\ blocking parameters are described
below.
.PP
Figure A\(hy1/X.140 illustrates the relationship between the
access delay
and the X.130\ parameter 
network post selection
delay
. Access delay here describes the total time between the user's
issuance of an X.21\ \fIcall request\fR and the network's subsequent issuance 
of 
\fIready for data\fR . The X.130\ parameter network post selection delay 
describes 
two specific network\(hydependent components of access delay.
.PP
Figure A\(hy2/X.140 illustrates the relationship between
disengagement delay
and the X.130\ parameter 
network clear
indication delay
. Two independent disengagement delays are
identified:
.RT
.LP
	1)
	Originator disengagement delay \(em the total time between
\fIDTE clear request\fR and \fIDCE ready\fR at the clearing DTE interface.
.LP
	2)
	 Non\(hyoriginator disengagement delay \(em the total time between \fIDTE 
clear request\fR at the clearing DTE interface and \fIDCE ready\fR at the 
cleared DTE interface.
.PP
Network clear indication delay contributes directly to
non\(hyoriginator disengagement delay, but does not include the delays 
associated with issuance of the \fIDTE clear confirmation\fR and \fIDCE 
ready\fR signals at the 
cleared DTE interface.
.PP
Access denial probability corresponds to the probability of blocking in 
the X.21\ application. It includes cases where no \fInetwork congestion\fR 
signal is issued. 
.PP
The X.140 access and disengagement parameters may be used to describe the 
quality of X.21 leased circuit services by simply specifying their values 
as zero. 
.RT
.LP
.rs
.sp 27P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.ce
\fBH.T. [T2.140]\fR 
.ce
TABLE\ A\(hy1/X.140
.ce
\fBQualitative relationships between the general parameters
.ce
\fBand the circuit\(hyswitched parameters\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
lw(102p) | cw(42p) sw(42p) | cw(42p) , ^  | c | c | c.
T{
Circuit\(hyswitched parameters
(X.21 protocol)
General parameters
T}	Delay (X.130)	Blocking (X.131)
	Network post  selection delay	T{
Network clear
indication delay
T}	T{
Probability non\(hyconnection due to congestion
(blocking probability)
T}
_
.T&
lw(102p) | cw(42p) | lw(42p) | lw(42p) .
Access delay	\(sq		
_
.T&
lw(102p) | cw(42p) | lw(42p) | lw(42p) .
Incorrect access probability			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
Access denial probability			\(sq
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
User information transfer delay
T}			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
User information transfer rate
T}			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
User information error probability
T}			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
Extra user information delivery probability
T}			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
User information misdelivery probability
T}			
_
.T&
lw(102p) | cw(42p) | lw(42p) | cw(42p) .
T{
User information loss probability
T}			
_
.T&
lw(102p) | cw(42p) | cw(42p) | cw(42p) .
Disengagement delay		\(sq	
_
.T&
lw(102p) | cw(42p) | cw(42p) | cw(42p) .
T{
Disengagement denial probability
T}			
_
.T&
lw(102p) | cw(42p) | cw(42p) | cw(42p) .
Service availability			
_
.T&
lw(102p) | cw(42p) | cw(42p) | cw(42p) .
T{
User information transfer denial probability
T}			
_
.T&
lw(102p) | cw(42p) | cw(42p) | cw(42p) .
Service outage duration			
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau A\(hy1/X.140 [T2.140] p. 19 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.LP
.rs
.sp 23P
.ad r
\fBFigure A\(hy1/X.140, p. 20\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.rs
.sp 23P
.ad r
\fBFigure A\(hy2/X.140, p. 21\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.ce 1000
ANNEX\ B
.ce 0
.ce 1000
(to Recommendation X.140)
.sp 9p
.RT
.ce 0
.ce 1000
\fBRelationships between the general QOS parameters and the\fR 
.sp 1P
.RT
.ce 0
.ce 1000
\fBpacket\(hyswitched service performance parameters\fR 
.ce 0
.PP
This annex describes relationships between the general QOS
parameters defined in Recommendation\ X.140 and the X.25\(hybased, packet\(hyswitched 
service performance parameters for which limits are specified in X.130\(hyseries 
Recommendations. It illustrates a second application of the general parameters 
and provides a framework for relating user QOS needs with the performance 
capabilities of packet\(hyswitched PDNs. Such relationships may be defined 
either to allocate a user requirement among network elements, in cases 
where the 
network performance values are selectable, or to derive resultant QOS values
from network performance values, in cases where the latter values are fixed.
.sp 1P
.RT
.PP
In the example presented here, it is assumed that quality is to be specified 
in terms of packet\(hylayer reference events observed at the physical 
boundaries separating communicating DTEs from their adjacent access circuit
sections. It is assumed that Recommendation\ X.25 procedures are used on the
access circuit sections. The section boundaries and the specific packet
reference events are defined in Recommendation\ X.134. The packet\(hyswitched
service performance parameters are defined in Recommendations\ X.135\(hyX.137. 
The call set\(hyup and clearing sequences presented here are derived from 
state 
diagrams presented in Annex\ B of Recommendation\ X.25.
.PP
Table B\(hy1/X.140 lists the general parameters and the packet\(hyswitched 
service parameters in the rows and columns of a matrix and indicates 
qualitative relationships between them. Each set of parameters is grouped in
four categories: access parameters, user information transfer parameters,
disengagement parameters, and availability parameters.
.PP
A mark at a particular row/column intersection in the matix
indicates that the corresponding parameters are interdependent and should be
considered jointly in service performance specification. Each general parameter 
is influenced by one or more packet\(hyswitched service parameters, and 
may 
influence their values if the latter are selectable. Detailed relationships
between the general parameters and corresponding X.135\(hyX.137 parameters are
described below.
.PP
The relationship between access delay and call set\(hyup delay is
illustrated in Figure\ B\(hy1/X.140. As described in Recommendation\ X.135, 
call 
set\(hyup delay can be defined either at a single virtual connection section
boundary or between two section boundaries. When defined at the calling DTE
boundary\ B\d1\u, call set\(hyup delay differs from access delay in only one
respect:
it includes the modulation time\ (X) of the call request packet on the 
calling DTE access circuit section, while access delay does not. When defined 
between the calling and called DTE boundaries\ B\d1\uand\ B\dn\u, call 
set\(hyup delay 
differs from
access delay in one additional respect: it excludes the called DTE response
time (i.e., the call set\(hyup delay at boundary\ B\dn\u).
.PP
The general parameters user information transfer delay and
disengagement delay correspond closely with the packet\(hyswitched service
parameters data packet transfer delay and call clearing delay, respectively,
when each parameter is defined at the X.25\ DTE boundaries. Data packet 
transfer delay includes the modulation time\ (Y) of the data packet on 
the originating 
DTE access circuit section, while user information transfer delay does not.
Similarly, call clearing delay includes the modulation time (Z) of the clear
request packet on the clearing DTE access circuit section, while disengagement 
delay does not. 
.PP
The general parameters incorrect access probability, access denial
probability, and disengagement denial probability are essentially identical 
to the packet\(hyswitched service parameters call set\(hyup error probability, 
call 
set\(hyup failure probability, and call clear failure probability, respectively, 
as defined at the X.25\ DTE boundaries. The packet\(hyswitched service 
parameter 
throughput capacity expresses the maximum continuously achievable
(steady\(hystate) value of the general parameter user information transfer 
rate; the former parameter also differs from the latter in that its definition 
allows it to be measured at a single boundary. 
.bp
.RT
.ce
\fBH.T. [T3.140]\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(342p) .
TABLE\ B\(hy1/X.140
.T&
cw(342p) .
T{
\fBQualitative relationships between the general parameters
\fBand the packet\(hyswitched service parameters\fR
T}
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
Packet\(hyswitched
service parameters
(X.25 protocol)
General parameters
T}	Call set\(hyup delay	T{
Call set\(hyup error probability
T}	T{
Call set\(hyup failure probability
T}	Data packet transfer delay	Through put capacity	Residual error rate	Reset stimulus probability	Reset probability	T{
Premature disconnect stimulus probability
T}	T{
Premature disconnect probability
T}	Clear indication delay	T{
Call clear failure probability
T}	Service availability	T{
Mean time between service outages
T}
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Access delay	\(sq													
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Incorrect access probability		\(sq												
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Access denial probability			\(sq											
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information transfer delay
T}				\(sq										
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information transfer rate
T}					\(sq									
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information error probability
T}						\(sq								
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
Extra user information delivery probability
T}						\(sq								
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information misdelivery probability
T}						\(sq								
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information loss probability
T}						\(sq	\(sq	\(sq	\(sq	\(sq  				
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Disengagement delay											\(sq			
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
Disengagement denial probability
T}												\(sq		
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Service availability													\(sq	
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
T{
User information transfer denial probability
T}													\(sq	
_
.T&
lw(64p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) | cw(22p) | cw(22p) | cw(16p) .
Service outage duration														\(sq
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau B\(hy1/X.140 [T3.140] p. 22, (\*`a l'italienne)\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.LP
.rs
.sp 29P
.ad r
\fBFigure B\(hy1/X.140, p. 23\fR 
.sp 1P
.RT
.ad b
.RT
.PP
The packet\(hyswitched service parameter residual error rate combines the 
three general parameters user information error probability, extra user 
information delivery probability, and user information loss probability in a
single composite accuracy measure. The mathematical relationship between
residual error rate and the three general parameters is specified in
Recommendation\ X.136. There is no packet\(hyswitched service parameter that
corresponds directly with the general parameter user information misdelivery
probability; however, misdelivered data is counted as extra data under the
Recommendation\ X.136 definitions, and is thus reflected indirectly in the
definition of residual error rate. The reset and premature disconnect
parameters defined in Recommendation\ X.135 are protocol dependent and 
thus have no direct counterparts among the general parameters specified 
in 
Recommendation\ X.140. Their values will normally influence the X.140\ 
parameter user information loss probability. 
.RT
.PP
Both Recommendation X.137 and Recommendation X.140 define a
measure of service availability. The former measure specializes the latter 
by identifying the particular decision parameters and thresholds that are 
to be 
used in defining outages in a packet\(hyswitched service. Recommendation\ X.140
defines a closely\(hyrelated general parameter, user information transfer 
denial probability, that provides a sampled measure of unavailability. 
It is based on a specific definition of outage that differs from that presented 
in 
Recommendation\ X.137 in one respect: the former definition includes only 
user information transfer parameters among the supported (decision) parameters 
used in identifying outages, while the latter definition includes call 
set\(hyup 
parameters as well. The X.140 parameter service outage duration and the 
X.137 parameter mean time between service outages provide complementary 
information on the frequency of transitions between the available and unavailable 
states.
.bp
.ce 1000
ANNEX\ C
.ce 0
.ce 1000
(to Recommendation X.140)
.sp 9p
.RT
.ce 0
.ce 1000
\fBRelationships between the general QOS parameters 
.sp 1P
.RT
.ce 0
.ce 1000
\fBand the OSI network layer service performance parameters\fR 
.ce 0
.PP
This annex describes relationships between the general QOS
parameters defined in Recommendation\ X.140 and the OSI network service 
(NS) performance 
.FS
Recommendation X.213 distinguishes QOS parameters which
describe performance from those which describe other service characteristics
[network connection (NC) protection priority, and maximum acceptable cost]. 
Only the former parameters are addressed here. 
.FE
parameters defined in
Recommendation\ X.213. It illustrates application of the general parameters 
to a specific (abstract) OSI service interface \(em the interface between 
the transport and network layers. 
.sp 1P
.RT
.PP
Table C\(hy1/X.140 lists the general parameters and the NS
performance parameters in the rows and columns of a matrix and indicates
qualitative relationships between them. Each set of parameters is
grouped in four categories: access parameters, user information transfer
parameters, disengagement parameters, and availability
parameters.
.FS
Transfer failure probability is included among the user
information (data) transfer parameters in Recommendation\ X.213; that
Recommendation does not identify availability as a separate parameter
category.
.FE
.PP
Recommendation X.213 defines exact counterparts to five X.140
parameters: access delay, user information transfer delay, user information
transfer rate, disengagement delay, and disengagement denial
probability.
.PP
The X.140 parameters subdivide the X.213 parameters into
more
detailed components in two cases. The X.213 parameter NC establishment 
failure probability subsumes two X.140 parameters: access denial probability 
and 
incorrect access probability. Values for the X.140 parameters could be 
added to calculate their X.213 counterpart. The X.213 parameter residual 
error rate 
subsumes four X.140 parameters: user information loss probability, user
information misdelivery probability, extra user information delivery
probability, and user information error probability. The relationships among
these probabilities are illustrated in Figure\ C\(hy1/X.140. Each parameter is
normalized so that its possible values range between\ 0 and\ 1.
.RT
.PP
The X.213 parameter NC Resilience is protocol dependent and this has no 
direct counterpart among the general parameters specified in 
Recommendation\ X.140. Its value will normally influence the X.140\ parameter
user information loss probability.
.PP
The X.140 parameter user information transfer denial probability
corresponds closely with the X.213 parameter transfer failure probability; 
the two differ only in the detailed definition of the supported (decision) 
parameters used in defining transfer denial (or failure).
.PP
Two X.140 parameters have no X.213 counterparts: service outage
duration and service availability.
.RT
.LP
.sp 10
.bp
.ce
\fBH.T. [T4.140]\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(342p) .
TABLE\ C\(hy1/X.140
.T&
cw(342p) .
T{
\fBQualitative relationships between the general parameters and\fR
\fBthe OSI network layer service performance QOS parameters\fR
T}
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
OSI network service
parameters
(X.213)
General parameters
T}	NC establishment delay	T{
NC establishment failure probability
T}	Transit delay	Throughput	Residual error rate	NC resilience	NC release delay	T{
NC release failure probability
T}	Transfer failure probability
_
.T&
lw(72p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
Access delay	\(bu								
_
.T&
lw(72p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
Incorrect access probability		\(sq							
_
.T&
lw(72p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
Access denial probability		\(sq							
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
User information transfer delay
T}			\(bu						
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
User information transfer rate
T}				\(bu					
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
User information error probability
T}					\(sq				
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
Extra user information delivery probability
T}					\(sq				
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
User information misdelivery probability
T}					\(sq				
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) | lw(30p) .
T{
User information loss probability
T}					\(sq	\(sq			
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) | lw(30p) .
Disengagement delay							\(bu		
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) .
T{
Disengagement denial probability
T}								\(bu	
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | lw(30p) .
Service availability									
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
User information transfer denial probability
T}									\(sq
_
.T&
lw(72p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) | cw(30p) .
T{
Service outage duration
\(bu
General parameter is identical to the corresponding X.213
parameter when specialized to the OSI network service
interface.
.line
\(sq
Corresponding parameters are interdependent but not
identical.
.parag
T}									
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau C\(hy1/X.140 [T4.140], p. 24, (\*`a l'talienne)\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.bp
.LP
.rs
.sp 30P
.ad r
\fBFigure\ C\(hy1/X.140, p. 25\fR 
.sp 1P
.RT
.ad b
.RT
.sp 2P
.LP
\fBRecommendation\ X.141\fR 
.RT
.sp 2P
.ce 1000
\fBGENERAL\ PRINCIPLES\ FOR\ THE\ DETECTION\ AND\ CORRECTION\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Rec.\ X.141''
.OF '''Fascicle\ VIII.3\ \(em\ Rec.\ X.141	%'
.ce 0
.sp 1P
.ce 1000
\fBOF\ ERRORS\ IN\ PUBLIC\ DATA\ NETWORKS\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Malaga\(hyTorremolinos, 1984)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIconsidering\fR 
.sp 9p
.RT
.PP
(a)
that errors have to be detected and corrected with a
very high degree of reliability;
.PP
(b)
that some error correction procedures may be more
advantageous than others depending on transmission delays in the network 
and on the distribution (with time) of errors; 
.PP
(c)
that the distribution (with time) of errors at the ends of a path may depend 
on forward error correction procedures implemented in one or more of the 
path segments; 
.LP
.PP
(d)
that the applicability of some error correction
procedures may be affected by the number of satellite systems in the
connection, which may be in national or international links or in the Maritime 
Mobile Service; 
.PP
(e)
that different error correction procedures may be
concatenated in some connections,
.bp
.sp 1P
.LP
\fIunanimously recommends\fR 
.sp 9p
.RT
.PP
that the general principles identified in this Recommendation be taken 
into account in the design and application of procedures for the 
detection and correction of errors in public data networks.
.sp 2P
.LP
\fB1\fR 	\fBGeneral\fR 
.sp 1P
.RT
.PP
1.1
The purpose of this Recommendation is to describe general
principles applicable to the detection and correction or recovery of 
link   transmission errors
in public data networks.
.sp 9p
.RT
.PP
1.2
Two fundamental objectives of 
error control procedures
are:
.LP
	\(em
	to ensure an incidence of undetected errors that is within
acceptably low probability limits;
.LP
	\(em
	to ensure that detected errors are corrected or recovered
using an error control procedure consistent with data throughput
and sequencing requirements which apply when the error rate of
the Physical Layer is within the fully acceptable and the
tolerance limits of specified performance.
.PP
1.3
In the context of the Reference Model of 
Open Systems
Interconnection
, it is noted in Recommendation\ X.200 that each\ (N) peer
protocol should include sufficient control information to enable the\ (N)
entities to detect or recover from error conditions within its purview.
Reporting detected but unrecovered errors is a service that must be provided 
by each layer. 
.PP
Specifically, it is an objective of the 
Data Link Layer
to detect and possibly correct errors which may occur in the 
Physical
Layer
.
.LP
.PP
1.4
For any particular error detection arrangement the probability of undetected 
errors will generally tend to increase: 
.sp 9p
.RT
.LP
	\(em
	with increasing error rate,
.LP
	\(em
	 for any given error rate, as the error distribution becomes less random 
and as the length of error bursts increases, 
.LP
	\(em
	with increasing frame length,
.LP
	\(em
	possibly due to scrambling arrangements which may have
factors in common with the 
generating polynomial
used
for 
error detection
.
.PP
1.5
Data throughput in the presence of errors depends on the design
of the error control procedure, which in turn depends on the following
conditions:
.LP
	\(em
	error rate,
.LP
	\(em
	error distribution,
.LP
	\(em
	scrambling and/or multiplexing arrangements insofar as they
affect the 
error distribution
or 
error rate
,
.LP
	\(em
	transmission path (propagation) time delay,
.LP
	\(em
	data signalling rate,
.LP
	\(em
	frame length,
.LP
	\(em
	window size,
.LP
	\(em
	buffer memory resources at the sending and receiving end of   the link.
.sp 2P
.LP
\fB2\fR 	\fBTypes of error occurrences\fR 
.sp 1P
.RT
.PP
Error occurrences are typically of three types distinguished by
characteristic error distributions with time:
.RT
.LP
\fR 	\(em
	random errors,
.LP
	\(em
	burst errors,
.LP
	\(em
	errors due to uncontrolled slip.
.PP
It is likely that one type of error occurrence will be predominant in any 
particular link, depending on the type of transmission systems employed 
(i.e.\ cable, microwave radio relay, or satellite, with or without forward 
error correction). 
.PP
In the design of error control procedures for a link, it is important to 
identify any tendency for the predominance of a particular type of error 
occurrence.
.bp
.RT
.LP
.sp 2P
.LP
\fB3\fR 	\fBError control procedures\fR 
.sp 1P
.RT
.sp 1P
.LP
3.1
	\fITypes of procedure\fR 
.sp 9p
.RT
.PP
Two types of error control commonly employed in public data
networks (PDNs) are:
.RT
.LP
	\(em
	forward error correction, a coding method employed with the
objective of detecting and correcting errors in received data
instead of requesting retransmission,
.LP
	\(em
	ARQ procedures wherein transmitted information is formatted
in frames with error detection encoding, and error recovery is
achieved by automatic repetition upon request from the data
receiver of a frame or of all information already transmitted
starting with the requested frame. Timeout recovery serves as
a backup for the ARQ procedure.
.sp 1P
.LP
3.2
	\fIForward error correction\fR 
.sp 9p
.RT
.PP
Forward error correction (FEC) does not require the provision of a backward 
mechanism in order to operate. FEC is usually applied at the 
Physical Layer of the reference model, typically within transmission systems
whose error performance might not otherwise meet required limits.
.PP
The capability of FEC techniques commonly used in PDNs to control
errors tends to be restricted to the correction of a limited number of 
errors (typically 2 or 3\ errors) within each coded information block or 
constraint of block length. For this reason these FEC procedures are most 
effective in 
of situations where error occurrences are predominantly random.
.PP
Depending on multiplexing arrangements and sometimes on other
arrangements in the Physical Layer such as scrambling and encryption, residual 
uncorrected errors after FEC may tend to be grouped in clusters or error 
bursts. When the number of errors within a coded information frame or
constraint length of code exceeds the correction capability of the FEC
algorithm, the total number of errors in the cluster or burst may be increased 
rather than reduced by the FEC facility. 
.PP
Usually, it will not be feasible to notify the Data Link Layer of
detected but uncorrected errors via FEC facilities of the Physical Layer 
which may perform their error control function at a multichannel, multiplexed 
signal level of the transmission system. 
.PP
In the adaption of data signals at recommended bit rates below
64\ kbit/s for transmission at 64\ kbit/s, sufficient redundancy will be
introduced in some cases for forward error correction to be undertaken on a
majority voting basis without special forward error correction encoding. 
With this arrangement, a large number of different error patterns can be 
detected 
and corrected.
.PP
Alternatively, or in addition, the frame checking sequence of
the ARQ error control procedure may also be used to distinguish between
correctly and incorrectly received information in redundant signal
streams.
.RT
.sp 2P
.LP
3.3
	\fIARQ procedures\fR 
.sp 1P
.RT
.sp 1P
.LP
3.3.1
	\fIGeneral\fR 
.sp 9p
.RT
.PP
ARQ procedures
require the provision of forward and
backward channels, usually with simultaneous transmission capability.
.PP
ARQ control procedures of error detection and error recovery are
included in the functions of the Data Link Layer and may also be implemented 
in the functions of higher layers of the reference model. 
.RT
.LP
.sp 2P
.LP
3.3.2
	\fIError detection\fR 
.sp 1P
.RT
.sp 1P
.LP
3.3.2.1
	\fIFrame checking sequence\fR 
.sp 9p
.RT
.PP
The 16\(hybit frame checking sequence (FCS) described below is used for 
error detection in the packet transfer procedures of Recommendations\ X.25 
and\ X.75, in the Signalling System No.\ 7 signalling link procedure of 
Recommendation\ Q.703 and in the Link Access Procedure on the D\(hychannel 
of an 
ISDN as described in Recommendation\ Q.921\ (I.441).
.PP
The same generator polynomial is also used in the encoding and
checking process of Recommendation\ V.41.
.bp
.PP
The 16 FCS bits are generated at the transmitter. They are the\ 1s
complement of the sum (modulo\ 2) of:
.RT
.LP
	1)
	 the remainder of \fIx\fR \uD\dlFh\fR (\fIx\fR \u1\d\u5\d\ +\ \fIx\fR 
\u1\d\u4\d\ +\ \fIx\fR \u1\d\u3\d\ +\ .\|.\|.\ +\ \fIx\fR \u2\d\ +\ \fIx\fR 
\ +\ 1) 
divided (modulo\ 2) by the generator
polynomial \fIx\fR \u1\d\u6\d\ +\ \fIx\fR \u1\d\u2\d\ +\ \fIx\fR \u5\d\ +\ 1,
where \fIh\fR is the number of bits
in the frame existing between, but not including, the final bit of the 
opening flag and the first bit of the FCS, excluding bits inserted for 
transparency, 
and
.LP
	2)
	 the remainder after multiplication by \fIx\fR \u1\d\u6\d and then division 
(modulo\ 2) by the generator polynomial 
\fIx\fR \u1\d\u6\d\ +\ \fIx\fR \u1\d\u2\d\ +\ \fIx\fR \u5\d\ +\ 1 of the 
content of the 
frame existing between, but not including the final bit of the opening 
flag and the first bit of the FCS, excluding bits inserted for transparency. 
.PP
As a typical implementation, at the transmitter, the initial
remainder of the division is preset to all 1s and is then modified by division 
by the generator polynomial (as described above) on the address, control 
and 
information fields; the 1s complement of the resulting remainder is transmitted 
as the 16\(hybit\ FCS sequence. 
.PP
At the receiver the correspondence between the check bits and the
remaining part of the frame is checked. If a complete correspondence is not
found the appropriate error recovery procedure is initiated.
.PP
As a typical implementation at the receivers, the initial remainder is 
preset to all 1s, and the serial incoming protected bits including the 
check 
bits (after the bits inserted for transparency are removed) when multiplied 
by \fIx\fR \u1\d\u6\d and then divided by the generator polynomial will 
result in a 
remainder of 0001110100001111 (\fIx\fR \u1\d\u5\d through\ \fIx\fR \u0\d, 
respectively) in the absence of transmission errors. 
.PP
Explanatory notes concerning the FCS error detection procedure
described above are given in Appendix\ I.
.PP
The procedure will detect:
.RT
.LP
	a)
	all odd numbers of errors within a frame,
.LP
	b)
	any 
error burst
not exceeding 16\ bits in length,
.LP
	c)
	all two\(hybit errors when the code length is less than
32768\ bits,
.LP
	d)
	a large percentage of other error patterns (with even
numbers of errors).
.sp 1P
.LP
3.3.2.2
	\fIUse of\fR 
\fIscramblers\fR 
.sp 9p
.RT
.PP
The following system design consideration should be taken into
account concerning the use of self\(hysynchronizing scramblers:
.PP
Where 
self\(hysynchronizing scramblers
(i.e.\ scramblers which
effectively divide the message polynomial by the scrambler polynomial at the
transmitter and multiply the received polynomial by the scrambler polynomial 
at the receiver) are used, the scrambler polynomial and the generating 
polynomial for error detection must have no common factors in order to 
ensure satisfactory performance of the error\(hydetecting system. Where 
this condition cannot be 
maintained, the scrambling process must precede the error detection encoding
.PP
process and the descrambler process must follow the error detection decoding
process. Where additive (i.e.\ non\(hyself\(hysynchronizing) scramblers 
are used or 
where the scrambling takes place at a multi\(hychannel multiplexed signal 
level, this design precaution need not be observed. 
.RT
.sp 1P
.LP
3.3.2.3
	\fIFrame integrity\fR 
.sp 9p
.RT
.PP
The integrity of the frame format must be maintained in order to
assure proper functioning of the error detection procedure described in
\(sc\ 3.3.2.1.
.PP
The frame structure for all transmissions is distinguished by opening and 
closing flags, each consisting of one\ 0 followed by six contiguous\ 1s 
and one\ 0. A single flag may be used as both the 
closing flag
for one frame and the 
opening flag
for the next frame. To ensure that the unique flag sequence is not simulated, 
the entire frame content between two flag sequences is examined at the 
transmitter and a 0\ bit is inserted after all sequences of 5\ contiguous 
1\ bits (including the last 5\ bits of the FCS). At the receiver, 
the frame content is reexamined and any 0\ bit which directly follows
5\ contiguous 1\ bits is discarded.
.PP
At the receiver, a frame validity check is carried out to detect any invalid 
frames not properly bounded by two flags or having fewer than the 
specified minimum number of bits. Invalid frames are treated in the same 
way as frames with detected errors. 
.bp
.RT
.sp 1P
.LP
3.3.3
	\fIError recovery procedures\fR 
.sp 9p
.RT
.PP
In accordance with ARQ concepts, error recovery is vested in the
traffic control procedure wherein all information frames are numbered
sequentially in order of transmission, from\ 0 through modulus minus\ 1 (where
\fImodulus\fR is the modulus of the sequence numbers). Typically, the modulus
equals\ 8 or\ 128 and the sequence numbers cycle through the entire range.
.PP
Valid frame without errors received in proper sequence are
acknowledged in responses from the receiver to the transmitter, while invalid 
frames and frames with errors are discarded by the receiver and completely 
ignored. Frame recovery action is initiated by the receiver when a valid 
frame without errors does not have the expected sequence number. Consequently, 
when one or more frames are discarded for lack of validity or for errors, 
the number of the next correctly received frame will be out of sequence, 
causing the 
receiver to initiate the prescribed frame recovery procedure.
.PP
If, due to a transmission error, the receiver does not receive (or
receives and discards) a single information frame or the last in a sequence 
of information frames, then the out\(hyof\(hysequence condition which would 
otherwise 
serve to initiate error recovery procedures at the receiver will not be
detected. In this case, frame recovery will be initiated at the transmitter 
via a time\(hyout procedure as follows: 
.PP
For traffic control purposes, the receiver must send acknowledgment
response to the transmitter confirming the receipt of valid, error free 
frames. After a specified time\(hyout period with outstanding transmitted 
frames and no 
acknowledgement or frame recovery responses from the receiver, appropriate
recovery action is initiated at the transmitter to determine the point 
at which retransmission must begin. 
.PP
Alternative types of error recovery procedure are available as
follows:
.RT
.LP
	\(em
	reject procedure,
.LP
	\(em
	selective reject procedure,
.LP
	\(em
	selective reject\(hyreject procedure.
.LP
.PP
Each of these procedures requires that storage be provided at the transmitter 
for all information frames already sent but not yet acknowledged to be 
correctly received. 
.PP
The data throughput efficiency obtainable as a function of error rate and 
distribution may depend significantly on the type of error recovery 
procedure, particularly in transmission links with associated long time 
delays (e.g.\ links via satellite). The complexity of error recovery implementation, 
including frame storage requirements at the receiver, is another consideration 
which plays an important part in selecting the most advantageous error 
recovery procedure to suit a particular situation. 
.RT
.sp 1P
.LP
3.3.3.1
	\fIReject (REJ) procedure\fR 
.sp 9p
.RT
.PP
The 
\fIreject\fR \|(REJ) error recovery procedure
is used by the receiver to request retransmission of information frames 
commencing with a specified sequence number and to simultaneously acknowledge 
satisfactory 
reception of all preceding information frames.
.PP
The rejected frame and all subsequent information frames already in
transit at the time that the REJ response reaches the transmitter will be
retransmitted.
.PP
After sending the REJ response, the receiver discards all incoming
information frames until the lost frame is recovered. This procedure minimizes 
frame storage requirements at the receiver, but under marginal conditions 
of 
error performance it may result in poor throughput efficiency depending 
on the round\(hytrip transmission delay between the transmitter and receiver. 
.PP
With the REJ error recovery procedure, the window size should allow a maximum 
number \fIk\fR of outstanding frames, where \fIk\fR is the smallest integer 
not less than \fIr\fR , calculated as follows: 
\v'6p'
.RT
.sp 1P
.ce 1000
\fIr\fR = 
@ {\fIT\fR \(mu \fID\fR } over {\fIL\fR } @ 
.ce 0
.sp 1P
.LP
.sp 1
.LP
where
.LP
	\fIT\fR 	is the transmission rate (bit/s)
.LP
	\fID\fR 	is the round\(hytrip delay (seconds)
.LP
	\fIL\fR 	is the information frame length (bits).
.bp
.sp 1P
.LP
3.3.3.2
	\fISelective reject procedure\fR 
.sp 9p
.RT
.PP
The \fIselective reject\fR \|(SREJ) response is used by the receiver to 
request retransmission of a single information frame identified by its 
sequence number and to simultaneously acknowledge satisfactory reception 
of all preceding information frames. 
.PP
In accordance with the foregoing definition of the SREJ request, only one 
SREJ condition can be outstanding at any one time. Consequently, the 
ability of the SREJ procedure to make efficient use of the Physical Layer 
falls off very quickly as the rate of frame error occurrence exceeds one 
per 
round\(hytrip propagation delay.
.PP
This difficulty may be alleviated by an alternative SREJ procedure
which suppresses the acknowledgement function of the SREJ request and
consequently allows a station to send a following 
SREJ request
for
retransmission of another fault information frame before the information 
frame in response to the first SREJ request has been correctly received. 
This 
alternative procedure can be particularly advantageous in the case of high
speed transmission via satellite.
.PP
Pursuant to the alternative procedure, the selective reject frame
SREJ is used to request retransmission of a single information frame numbered 
N(R) and the information frames numbered up to N(R)\ \(em\ 1 are not considered 
as accepted. 
.PP
Subsequent information frames already in transit when the SREJ
response reaches the transmitter will not be repeated (if received correctly). 
Hence, there is a minimum reduction in throughput efficiency as a function 
of increasing error rate on transmission paths with long time delays. 
.PP
This advantage of the SREJ procedure, is realized at the cost of
providing considerable frame storage capability and some processing for 
frame resequencing at the receiver. 
.PP
With the SREJ recovery procedure, the window size should allow a
maximum number \fIk\fR of outstanding frames where \fIk\fR is an integer 
not less than \fIr\fR \ as follows: 
\v'6p'
.RT
.sp 1P
.ce 1000
\fIr\fR = 2 
@ {\fIT\fR \(mu \fID\fR } over {\fIL\fR } @ 
.ce 0
.sp 1P
.LP
.sp 1
.sp 1P
.LP
3.3.3.3
	\fISelective reject\(hyreject procedure\fR 
.sp 9p
.RT
.PP
A proposed selective reject\(hyreject procedure is described below:
.PP
If the receiver detects the loss of a single information frame then, after 
satisfactory receipt of the next information frame, it sends a SREJ 
response to recover the lost frame. All information frames received
satisfactorily in sequence after the lost frame are stored at the receiver
pending recovery of the lost frame.
.PP
If the receiver detects the sequential loss of two information frames, 
it sends a REJ response and discards all subsequently received information 
frames until the lost frame is recovered.
.PP
If the loss of another information frame is detected prior to recovery 
from the SREJ exception condition, the receiver will store all information 
frames received subsequent to the first lost frame and prior to the second 
lost frame and will discard all information frames thereafter until the 
first lost frame is recovered. After recovery of the first lost frame, 
the receiver will send a REJ response for recovery of the second lost frame 
and the subsequently received but discarded frames. 
.PP
Operated over transmission paths with long time delays, the SREJ\(hyREJ 
error recovery procedure results in values of throughput efficiency as 
a 
function of error rate which are somewhat inferior to those obtained with 
the SREJ procedure and significantly better than those obtained with the 
REJ 
procedure.
.PP
For any prevailing error rate, the average occupancy of buffer memory for 
frame storage at the receiver with the SREJ\(hyREJ procedure is significantly 
less than corresponding average buffer occupancy with the SREJ procedure. 
.PP
With the SREJ\(hyREJ error recovery procedure, the window size should
allow a maximum number of outstanding frames, \fIk\fR , where\ \fIk\fR 
is the smallest 
integer not less than \fIr\fR calculated as follows:
\v'6p'
.RT
.sp 1P
.ce 1000
\fIr\fR = 2 
@ {\fIT\fR \(mu \fID\fR } over {\fIL\fR } @ 
.ce 0
.sp 1P
.LP
.sp 1
.bp
.sp 2P
.LP
\fB4\fR 	\fBConcatenation of error control procedure\fR 
.sp 1P
.RT
.sp 1P
.LP
4.1
	\fIConcatenation of FEC and ARQ procedures\fR 
.sp 9p
.RT
.PP
In links via satellite, the reduction in data throughput as a
function of increasing error rate may be minimized by the concatenated 
use of both forward error correction and ARQ procedures. 
.PP
Since forward error correction reduces the effective data throughput of 
the transmission medium under acceptable operating conditions when the 
error rate is low and is most effective for only a small percentage of 
the time when the error performance is marginal, the use of a more efficient 
ARQ procedure 
(e.g.\ SREJ instead of REJ) may be considered as an alternative to the
concatenation of FEC and ARQ procedures.
.RT
.LP
.sp 1P
.LP
4.2
	\fIConcatenation of FEC procedures\fR 
.sp 9p
.RT
.PP
The utilization of two stages of forward error correction (FEC)
coding may yield a very significant improvement in the performance of a
satellite link. Figure\ 1/X.141 illustrates the general configuration of 
such a two\(hystage concatenated coding system. The diagram shows two pairs 
of 
interleavers which are discussed below and may be omitted in some cases.
.RT
.PP
The purpose of the interleaver pairs is to break up bursts of
errors and to scatter these errors in a manner so as to minimize the
probability that a long uncorrectable error burst will be presented to a
decoder. The 
channel symbol interleaver pair
may be deleted if the
channel errors are known to be statistically independent. When an inner decoder
.PP
error occurs, the decoder will output a burst of errors. Therefore, it is
necessary to include an 
intercode interleaved pair
which is designed to transform the occasional inner decoder error bursts 
so that they can be 
efficiently corrected by the outer decoder. Thus, a well designed concatenated 
coding system includes codes and interleavers designed to complement each 
other. The inner code should correct nearly all of the channel errors and 
the outer code should correct the residual errors caused by inner decoder 
failures and errors. 
.RT
.LP
.rs
.sp 19P
.ad r
\fBFigure 1/X.141, p.16\fR 
.sp 1P
.RT
.ad b
.RT
.PP
A final consideration in the selection of a concatenated code is that of 
decoding delay and synchronization. Care must be taken in selecting the 
codes and interleavers to insure that: 
.RT
.LP
	1)
	the delay introduced by the FEC system is small with respect
to the satellite propagation time (approximately 250\ ms), and
.LP
	2)
	the data loss incurred due to a loss of synchronization is
minimized.
.bp
.ce 1000
APPENDIX\ I
.ce 0
.ce 1000
(to Recommendation X.141)
.sp 9p
.RT
.ce 0
.ce 1000
\fBExplanatory notes concerning the \fR \fBframe checking sequence\fR 
.sp 1P
.RT
.ce 0
.PP
The following abbreviations are used in the explanatory notes
given below:
.sp 1P
.RT
.LP
	\fIG\fR (\fIx\fR )
	is the polynomial representing the k\(hybit sequence
between the opening flag and the start of the FCS
.LP
	\fIP\fR (\fIx\fR )
	is the generator polynomial
(\fIx\fR \u1\d\u6\d\ +\ \fIx\fR \u1\d\u2\d\ +\ \fIx\fR \u5\d\ +\ 1)
.LP
	\fIL\fR (\fIx\fR )
	is the polynomial representing 16 contiguous ones,
(\fIx\fR \u1\d\u6\d\ +\ \fIx\fR \u1\d\u5\d\ +
\fIx\fR \u1\d\u4\d\ +\ .\|.\|.\|\ +\ \fIx\fR \ +\ 1)
.LP
	\fIR\fR (\fIx\fR )\ =\ 
FCS is the remainder obtained from the
modulo\ 2 division:
\v'6p'
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d \fIG\fR (\fIx\fR ) +
\fIx\fR \fI
\uk\d L\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @  =
\fIQ\fR (\fIx\fR ) + 
@ {\fIR\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @ 
.ce 0
.sp 1P
.LP
.sp 1
.PP
In the frame checking sequence (FCS), the multiplication of
\fIG\fR (\fIx\fR ) by \fIx\fR \u1\d\u6\d corresponds to shifting the message
\fIG\fR (\fIx\fR ) 16 places, thus providing the space of 16\ bits for the FCS.
.PP
The addition of \fIx\fR \uD\dlFk\fR \|\fIL\fR (\fIx\fR ) to
\fIx\fR \u1\d\u6\d\|\fIG\fR (\fIx\fR ) is equivalent to inverting the first 
16\ bits of 
\fIx\fR \u1\d\u6\d\|\fIG\fR (\fIx\fR ) and
corresponds to initializing the initial remainder to a value of all ones. 
This addition is provided to protect against the obliteration of leading 
flags, 
which may be non\(hydetectable if the initial remainder is zero. The complementing 
of \fIR\fR (\fIx\fR ), by the transmitter, at the completion of the division 
ensures that
the received, error\(hyfree message will result in a unique, non\(hyzero 
remainder at the receiver. The non\(hyzero remainder provides protection 
against potential 
non\(hydetectability of the obliteration of trailing flags.
.PP
At the transmitter, the FCS is added to \fIx\fR \u1\d\u6\d\|\fIG\fR (\fIx\fR )
and results in a total message \fIM\fR (\fIx\fR ) of length:
.RT
.sp 1P
.ce 1000
\fIn\fR = \fIk\fR + 16, where \fIM\fR (\fIx\fR ) = \fIx\fR \u1\d\u6\d\|\fIG\fR 
(\fIx\fR ) + 
\fIFCS\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.PP
At the receiver, the incoming \fIM\fR (\fIx\fR ) is multiplied by
\fIx\fR \u1\d\u6\d, added to \fIx\fR \uD\dlFn\fR \|\fIL\fR (\fIx\fR )
and divided by \fIP\fR (\fIx\fR ) as shown below:
\v'6p'
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d \fIM\fR (\fIx\fR ) +
\fIx\fR \fI
\un\d L\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @  =
@ {\fIx\fR \u16 \d [\fIx\fR \u16 \d \fIG\fR (\fIx\fR ) + \fIFCS\fR +
\fIx\fR \fI
\uk\d L\fR (\fIx\fR )]
} over {\fIP\fR (\fIx\fR )
} @ 
.ce 0
.sp 1P
.LP
.sp 1
.PP
The following expressions are derived from those shown above,
noting that the addition of \fIL\fR (\fIx\fR ) without carry to a polynomial
\fIR\fR (\fIx\fR )
of the same length is equivalent to a bit by bit inversion of
\fIR\fR (\fIx\fR )
and substituting
\fIFCS\fR \ =\ 
\fIR\fR (\fIx\fR )\ =\ \fIR\fR (\fIx\fR )\ +\ \fIL\fR (\fIx\fR ),
then rearranging the terms of the numerator:
\v'6p'
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d [\fIx\fR \u16 \d \fIG\fR (\fIx\fR ) +
\fIR\fR (\fIx\fR ) + \fIL\fR (\fIx\fR ) + \fIx\fR \fI
\uk\d\fR \fIL\fR (\fIx\fR )]
} over {\fIP\fR (\fIx\fR )
} @  =
.ce 0
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d [\fIx\fR \u16 \d \fIG\fR (\fIx\fR ) +
\fIx\fR \fI
\uk\d L\fR (\fIx\fR ) + \fIR\fR (\fIx\fR )] +
\fIx\fR \u16 \d \fIL\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @  =
\fIQr\fR (\fIx\fR ) +
@ {\fIRr\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @ 
.ce 0
.sp 1P
.LP
.sp 1
.PP
If the transmission is error\(hyfree, the term
[\fIx\fR \u1\d\u6\d\|\fIG\fR (\fIx\fR )\ +\ \fIx\fR \uD\dlFk\fR \|\fIL\fR 
(\fIx\fR )\ +\ \fIR\fR (\fIx\fR )] will be divisible by \fIP\fR (\fIx\fR 
) and the remainder after division will 
be:
\v'6p'
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d \fIL\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @ ,
.ce 0
.sp 1P
.LP
.sp 1
.LP
or\ 
0001110100001111 (\fIx\fR \u15
\d through
\fIx\fR \u0\d respectively).
.PP
.sp 1
If the transmission is error\(hyfree and the FCS is inverted before division 
at the receiver, the remainder will be zero because inverting the FCS is 
equivalent to adding another \fIx\fR \u1\d\u6\d\|\fIL\fR (\fIx\fR ) 
to the numerator and
\v'6p'
.sp 1P
.ce 1000
@ {\fIx\fR \u16 \d \fIL\fR (\fIx\fR ) + \fIx\fR \u16 \d \fIL\fR (\fIx\fR )
} over {\fIP\fR (\fIx\fR )
} @  = 0.
.ce 0
.sp 1P
.LP
.sp 1
.bp
.LP
.rs
.sp 10P
.LP
\fBMONTAGE:\ \fR PAGE PAIRE = PAGE BLANCHE
.sp 1P
.RT
.LP
.bp
.sp 1P
.ce 1000
\v'3P'
SECTION\ 5
.ce 0
.sp 1P
.ce 1000
\fBMAINTENANCE\fR 
.ce 0
.sp 1P
.sp 2P
.LP
\fBRecommendation\ X.150\fR 
.RT
.sp 2P
.ce 1000
\fBPRINCIPLES\ OF\ \fR \fBMAINTENANCE\ TESTING\ FOR\ PUBLIC\ DATA\ NETWORKS\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Rec.\ X.150''
.OF '''Fascicle\ VIII.3\ \(em\ Rec.\ X.150	%'
.ce 0
.ce 1000
\fBUSING\ DATA\ TERMINAL\ EQUIPMENT\ (DTE)\ AND\fR 
.ce 0
.sp 1P
.ce 1000
\fBDATA\ CIRCUIT\(hyTERMINATING\ EQUIPMENT\ (DCE)\ TEST\ LOOPS\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Geneva, 1980; amended at Malaga\(hyTorremolinos, 1984)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.LP
\fB1\fR 	\fBIntroduction\fR 
.sp 1P
.RT
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIconsidering\fR 
.sp 9p
.RT
.PP
(a)
the increasing use being made of data transmission
systems;
.PP
(b)
the volume of the information circulating on data
transmission networks;
.PP
(c)
the savings to be made by reducing interruption time on  such data circuits;
.PP
(d)
the importance of being able to determine
responsibilities (of necessity involving several parties) in maintenance
questions for networks; and
.PP
(e)
the advantages of standardization in this field,
.sp 1P
.LP
\fIunanimously declares\fR 
.sp 9p
.RT
.PP
that the locating of faults can be facilitated in many cases by
data circuit loop testing procedures in DTEs and DCEs.
.sp 2P
.LP
\fB2\fR 	\fBScope\fR 
.sp 1P
.RT
.PP
This Recommendation specifies the principles of maintenance testing for 
public data networks using the DTE/DCE test loops. The definition of the 
loops, the principles for the control of the loops and the principles for 
the indications to be presented when the loops are activated are described 
herein for general application with all DTE/DCE interfaces. Specific details 
concerning the implementation of these principles are contained in the
individual DTE/DCE interface Recommendations. The maintenance philosophy,
definitions and general principles are applicable to interface Recommendations, 
such as X.20, X.20\ \fIbis\fR , X.21, X.21\ \fIbis\fR , and\ X.22. 
.bp
.RT
.sp 1P
.LP
2.1
	\fIMaintenance philosophy\fR 
.sp 9p
.RT
.PP
The provision of DTE and DCE test loops in public data networks is based 
upon the following maintenance philosophy: 
.RT
.LP
	a)
	 test loops may be used by an Administration's test centre(s) to test 
the operation of either leased lines or circuit\(hyswitched network 
subscriber lines, including either all or part of the DCE, without necessarily 
requiring the dispatch of network maintenance personnel to the subscriber's 
premises;
.LP
	b)
	 where allowed by national testing principles, DCE test loops may also 
be used by a DTE to test the operation of network connection or leased 
lines. Where provided, the intent is for the DTE to make initial tests 
to 
isolate a trouble condition either in the DTEs or in the data circuit.
.sp 1P
.LP
2.2
	\fILoop testing principles\fR 
.sp 9p
.RT
.PP
The provision of loop testing capabilities should be based on the following 
principles: 
.RT
.LP
	a)
	the loops should be transparent, e.g.\ they should be bit
sequence independent;
.LP
	b)
	loop testing is a disruptive type of testing, e.g.\ when a
loop has been established transmission of data is not possible;
.LP
	c)
	 test loops may be established from any state; however, when loop testing 
is commenced from the \fIdata transfer\fR state, the same test 
procedures may be used for both leased lines and circuit\(hyswitched connections; 
.LP
	d)
	 when allowed, the preferred DTE test sequence is: loop\ 1 \(em loop\ 
2 \(em loop\ 3, sequentially from both ends of the circuit. 
.sp 2P
.LP
\fB3\fR 	\fBDefinition of the loops\fR 
.sp 1P
.RT
.PP
Nine loops are defined as shown in Figure 1/X.150. For clarity
these nine loops have been grouped as follows:
.RT
.LP
	a)
	DTE test loop \(em type 1 loop
	(\(sc\ 3.1)
.LP
	Loop 1
	(\(sc\ 3.1.1)
.LP
	b)
	Local test loops \(em type 3 loops
	(\(sc\ 3.2)
.LP
	Loop 3d
	(\(sc\ 3.2.1)
.LP
	Loop 3c
	(\(sc\ 3.2.2)
.LP
	Loop 3b
	(\(sc\ 3.2.3)
.LP
	Loop 3a
	(\(sc\ 3.2.4)
.LP
	c)
	Subscriber\(hyline test loops \(em type 4 loops
	(\(sc\ 3.3)
.LP
	Loop 4a
	(\(sc\ 3.3.1)
.LP
	Loop 4b
	(\(sc\ 3.3.2)
.LP
	d)
	Network test loops \(em type 2 loops
	(\(sc\ 3.4)
.LP
	Loop 2b
	(\(sc\ 3.4.1)
.LP
	Loop 2a
	(\(sc\ 3.4.2)
.sp 2P
.LP
3.1
	\fIDTE test loop \(em type 1 loop\fR 
.sp 1P
.RT
.sp 1P
.LP
3.1.1
	\fILoop 1\fR 
.sp 9p
.RT
.PP
This loop is used as a basic test of the operation of the DTE, by looping 
back the transmitted signals inside the DTE for checking. The loop 
should be set up inside the DTE as close as possible to the DTE/DCE interface.
.PP
Loop 1 may be established from either the \fIdata transfer\fR \|or \fIready\fR 
state. 
.PP
In some networks, for short routine tests during the \fIdata transfer\fR 
\|state, the DTE should either maintain the same status on the interchange 
circuits as before the test or where possible send the \fIDTE controlled 
not\fR 
\fIready\fR signal.
.bp
.RT
.LP
.rs
.sp 37P
.ad r
\fBFigure 1/X.150 p.17\fR 
.sp 1P
.RT
.ad b
.RT
.PP
If the loop is established from the \fIdata transfer\fR \|state, the
DCE
may continue to deliver data to the DTE during the test as though the DTE 
were in normal operation. It will be the responsibility of the DTEs to 
recover from any errors that might occur while the test loop is activated. 
.PP
If the loop is established from the \fIready\fR \|state, the DTE should
continue to monitor so that an incoming call may be given priority over a
routine test. Alternatively, in cases where the DTE cannot accept incoming
calls, DTEs shall signal one of the \fInot ready\fR states.
.PP
The DCE continues to present signal element timing and, if
implemented, byte timing. The DTE need not make use of the timing information 
during a loop test. 
.RT
.sp 1P
.LP
3.2
	\fILocal test loops \(em type 3 loops\fR 
.sp 9p
.RT
.PP
Local test loops (type 3 loops) are used to test the operation of the DTE, 
the 
interconnecting cable
and either all or parts of the local DCE, as discussed below.
.bp
.PP
Where allowed by national testing principles, loop\ 3 may be
established from any state.
.PP
For testing on leased circuits and for short duration testing on
circuit\(hyswitched connections, the DCE should either continue to present 
toward the line the conditions that existed before the test (e.g.\ either 
\fIdata\fR 
\fItransfer\fR or \fIready\fR state) or send the \fIcontrolled not ready\fR 
state to the 
remote DTE. Where this is not practical (e.g.\ in some cases for loop 3a) or
desirable (e.g.\ for long duration testing in circuit\(hyswitched applications), 
the DCE should terminate an existing call and, if possible, signal toward 
the subscriber\(hyline one of the \fInot ready\fR states. 
.PP
The DCE continues to present signal element timing, and, if
implemented, byte timing. The DTE must make use of the timing information.
.RT
.sp 1P
.LP
3.2.1
	\fILoop 3d\fR 
.sp 9p
.RT
.PP
This loop is used to test the operation of the DTE, including the inter\(hyconnecting 
cable, by returning transmitted signals to the DTE for 
checking. The loop is set up inside the local DCE and does not include
interchange circuit generators and loads. The DCE may make either type\ 2 or
type\ 4 loop tests during the loop\ 3d test condition.
.PP
\fINote\fR \ \(em\ While test loop 3d is operated, the effective length 
of the interface cable is doubled. Therefore, to insure proper operation 
of loop\ 3d, the maximum DTE/DCE interface cable length should be one\(hyhalf 
the length 
normally appropriate for the data signalling rate in use.
.RT
.sp 1P
.LP
3.2.2
	\fILoop 3c\fR 
.sp 9p
.RT
.PP
This loop is used to test the operation of the DTE, including the inter\(hyconnecting 
cable and DCE interchange circuit generators and loads. In 
this case, the Note in \(sc\ 3.2.1 concerning restrictions of interconnecting 
cable length does not apply. 
.RT
.sp 1P
.LP
3.2.3
	\fILoop 3b\fR 
.sp 9p
.RT
.PP
This loop is used as a test of the operation of the DTE and the
line coding and control logic and circuitry of the DCE. It includes all the
circuitry of the DCE, with the exclusion of the line signal conditioning
circuitry (e.g.\ impedance matching transformers, amplifiers, equalizers,
etc.). The delay between transmitted and received test data is a few octets.
.PP
\fINote\fR \ \(em\ In some DCEs, the setting of loop 3b will result in 
momentary loss of envelope alignment causing spurious signals to appear 
on receiving 
interchange circuits for a period of time. This may impact upon the DTE test
procedure. Refer to the DTE/DCE Recommendations for information regarding 
the signal element timing. In some networks, the setting of loop 3b will 
cause 
clearing of existing connections.
.RT
.sp 1P
.LP
3.2.4
	\fILoop 3a\fR 
.sp 9p
.RT
.PP
This loop is used to test the operation of the DTE and the DCE. The loop 
should include the maximum amount of circuitry used in DCE working 
including, in particular, the line signal conditioning circuitry. It is
recognized that, in some cases, the inclusion of devices (e.g.\ attenuators,
equalizers or test loop translators) may be necessary in the loopback path. 
The subscriber line is suitably terminated during a loop 3a\ test condition. 
The 
delay between transmitted and received test data is a few octets.
.PP
\fINote\fR \ \(em\ In some DCEs, the setting of loop 3a will result in 
momentary loss of envelope alignment causing spurious signals to appear 
on the receiving interchange circuits for a period of time. This may impact 
upon the DTE test 
procedure. Refer to the DTE/DCE interface Recommendations for information
.PP
regarding the signal element timing. In some networks, the setting of loop\ 
3a will cause clearing of existing connections. 
.RT
.sp 1P
.LP
3.3
	\fISubscriber line test loops \(em type 4 loops\fR 
.sp 9p
.RT
.PP
Subscriber line test loops (type 4 loops) are provided for the
maintenance of lines by the Administrations. The DCE signals to the local 
DTE a \fInot ready\fR or \fItest mode\fR state, as appropriate for the 
specific DTE/DCE 
interface. The DCE continues to present signal element timing and, if
implemented, byte timing.
.PP
\fINote\fR \ \(em\ In the case of loops 4 and 2 (see below) the DCE may 
signal the local DTE in such a manner that the DTE can distinguish a 
test mode
from a network failure.
.bp
.RT
.sp 1P
.LP
3.3.1
	\fILoop 4a\fR 
.sp 9p
.RT
.PP
This loop is only provided in the case of 4\(hywire subscriber lines. Loop\ 
4a is for the maintenance of lines by Administrations. When receiving and 
transmitting pairs are connected together, the circuit under test may not 
be 
measured as a data circuit. Loop\ 4a may be established inside the DCE 
or in a separate device. 
.RT
.LP
.sp 1P
.LP
3.3.2
	\fILoop 4b\fR 
.sp 9p
.RT
.PP
This loop is used by Administrations to test the operation of the subscriber 
line including the line signal conditioning circuitry in the DCE. 
When the receiving and transmitting circuits are connected at this point,
loop\ 4b provides a connection that can be considered as a data circuit.
.PP
\fINote\fR \ \(em\ The implementation may be such that some impairment of the
performance is expected since the DCE, in this case, does not perform a
complete signal regeneration/conversion.
.RT
.sp 1P
.LP
3.4
	\fINetwork test loops \(em type 2 loops\fR 
.sp 9p
.RT
.PP
Network test loops (type 2 loops) are used by the Administration's test 
centre(s) to test the operation of the leased line or subscriber line and 
either all or part of the DCE as discussed below. 
.PP
Where allowed by national testing principles, loop 2 may also be used by 
a DTE, as follows: 
.RT
.LP
	\(em
	 in case of switched circuit networks when the DTEs are in the \fIdata 
transfer\fR \|state, to test the operation of the network connection 
including the remote DCE;
.LP
	\(em
	in case of leased lines in the \fIready\fR \|state, to test the
operation of the line including the remote DCE.
.LP
.PP
The DCE signals the local DTE a \fInot ready\fR \|or \fItest mode\fR \|state 
as appropriate for the specific DTE/DCE interface (see Note to \(sc\ 3.3). 
The 
DCE continues to present signal element timing and, if implemented, byte
timing.
.sp 1P
.LP
3.4.1
	\fILoop 2b\fR 
.sp 9p
.RT
.PP
This loop is used by either the Administration's test centre(s)
and/or the remote DTE to test the operation of the subscriber line and 
all the circuitry of the DCE, with the exception of interchange circuit 
generators and loads. 
.RT
.sp 1P
.LP
3.4.2
	\fILoop 2a\fR 
.sp 9p
.RT
.PP
This loop is used by either the Administration's test centre(s) or the 
remote DTE to test the operation of the subscriber line and the entire 
DCE.
.PP
\fINote\fR \ \(em\ While in the loop 2a condition, the DCE may present 
an \fIopen\fR \fIcircuit\fR \|condition to the DTE on certain interchange 
circuits. It is assumed that the DCE detects electrical signal faults condition 
as \fInot ready\fR as 
appropriate for the specific electrical characteristics.
.RT
.LP
.sp 2P
.LP
\fB4\fR 	\fBMinimum implementation of test loops\fR 
.sp 1P
.RT
.sp 1P
.LP
4.1
	\fIDCE test loops\fR 
.sp 9p
.RT
.PP
Sufficient test loops should be provided in the DCE to allow the
customer and/or the Administration's maintenance personnel to positively
distinguish between DTE and DCE/line faults.
.PP
The DCE will implement at least one of the four local test loops
(type\ 3). The DCE will also implement at least one of the two network test
loops (type\ 2). The implementation of the loops within the DCE is a national
matter. Implementation of test loops beyond the minimum set specified above 
may be provided by some Administrations. 
.RT
.sp 1P
.LP
4.2
	\fIDTE test loops\fR 
.sp 9p
.RT
.PP
It is suggested that all new DTEs provide loop 1.
.bp
.RT
.sp 2P
.LP
\fB5\fR 	\fBLoop control\fR 
.sp 1P
.RT
.sp 1P
.LP
5.1
	\fIGeneral\fR 
.sp 9p
.RT
.PP
Where available, the means for remotely controlling a loop in one country 
from a location in another country are described in appropriate DTE/DCE 
interface Recommendations. 
.PP
In leased circuit services, subscriber\(hyline and network test loops
should not be activated before the customer has been informed. However, some
Administrations may activate these loops when abnormal conditions are detected 
in the network without first informing the customer. 
.PP
In circuit\(hyswitched services, subscriber\(hyline and network test loops 
should not be activated when the DTE is engaged in a call. In case of a 
collision between call request and the activation of these loops, the 
loop  activation command
will have priority and the call request will be
cancelled.  These loops may be activated without the prior knowledge and
agreement of the customer for periods which normally do not exceed one
second.
.RT
.sp 1P
.LP
5.2
	\fIControl of the local test loops\fR 
.sp 9p
.RT
.PP
To facilitate the testing of the DTE by the customer, manual
activation (by means of a switch of the DCE) will be provided for at least 
one of the four local test loops (type\ 3). The precise implementation 
is a national matter. However, customer\(hycontrolled automatic activation 
of the local test 
loops via the DTE/DCE interface should be considered.
.PP
Where available, the means for DTE control of these loops via signals in 
the DTE/DCE interface are described in the appropriate DTE/DCE interface 
Recommendations.
.PP
\fINote\fR \ \(em\ With the introduction of the electrical interchange 
circuits as defined in Recommenda 
tions\ X.26/X.27, some Administrations may locate the DCE in a location 
that is remote (up to 1000\ metres) from the DTE. Therefore, manual loop 
activation by the customer may be either difficult or impossible. Thus, 
some form of an automatic activation of these loops should be considered. 
Also the limitations in the Note of \(sc\ 3.2.1, loop\ 3d, should be 
considered.
.RT
.sp 2P
.LP
5.3
	\fIControl of the network test loops\fR 
.sp 1P
.RT
.sp 1P
.LP
5.3.1
	\fIGeneral\fR 
.sp 9p
.RT
.PP
Each network test loop implemented in the DCE will be activated
either by a manual switch on the DCE or remotely from the Administration's 
test centre(s) or both. The means for loop activation, the method for achieving 
remote control and the method for notifying the network of manual activation
are national matters. Random signals may be delivered to the DTE prior to
closing of loops.
.PP
Where loop 2a or 2b is provided for customer use, the procedure for
its use is subject to the relevant interface Recommendations.
.RT
.sp 2P
.LP
5.3.2
	\fILeased circuits\fR 
.sp 1P
.RT
.sp 1P
.LP
5.3.2.1
	\fIPoint\(hyto\(hypoint leased lines\fR 
.sp 9p
.RT
.PP
In case of point\(hyto\(hypoint line circuits, the Administrations will 
provide one or more of the following: 
.RT
.LP
	a)
	 customer control of the network test loop in the local DCE via a manually 
operated switch on the DCE; 
.LP
	b)
	customer control of the network test loop via the remote
DTE/DCE interface.
.LP
	\fINote\fR \ \(em\ The provision for the remote control of a loop in one
country from a location in another country is subject to
bilateral agreement between the affected Administrations.
.LP
	c)
	remote control from the Administration's 
data test
centre
.
.PP
When available, the method for activation of the network test loop in a 
DCE by a command signal from a remote DTE/DCE interface will be as 
described in the appropriate DTE/DCE interface Recommendation.
.bp
.LP
.sp 1P
.LP
5.3.2.2
	\fICentralized multipoint leased circuits\fR 
.sp 9p
.RT
.PP
The principle of maintenance testing for 
centralized multipoint circuits
are for further study. In this regard, the specific details
concerning the implementation of these principles are contained in the
individual DTE/DCE interface Recommendations.
.RT
.sp 1P
.LP
5.3.3
	\fISwitched networks\fR 
.sp 9p
.RT
.PP
In a similar manner to the technique decribed in \(sc\ 5.3.2.1 above, Administrations 
may provide a means for remotely controlling the network test loop from 
their test centre(s). This is recognized to be a national matter; 
however, if provided, the procedure to be used is described in the appropriate 
interface and signalling Recommendations. The remote control of network 
test 
loops in a DCE via the remote DTE/DCE interface is subject to bilateral
agreement between the affected Administrations.
.PP
\fINote\fR \ \(em\ Where allowed by national testing principles, the DTE may
establish a network test loop in the remote DCE when in the \fIdata transfer\fR 
state by means of a signal across the DTE/DCE interface. In this case, it
should be possible for the DTEs to re\(hyenter the data transfer state after
deactivation of the network test loop. It will be the responsibility of the
DTEs to recover from any errors that might occur while the test loop is
activated.
.RT
.LP
.sp 1P
.LP
5.4
	\fIControl of subscriber\(hyline test loops\fR 
.sp 9p
.RT
.PP
The provision of and use of subscriber\(hyline test loops is a
national matter. They are designed for the maintenance of lines by
Administrations in case of 4\(hywire subscriber lines.
.RT
.LP
.rs
.sp 33P
.LP
.bp
.LP
\fBMONTAGE: PAGE PAIRE = PAGE BLANCHE\fR 
.sp 1P
.RT
.LP
.bp
.sp 1P
.ce 1000
\v'3P'
SECTION\ 6
.ce 0
.sp 1P
.ce 1000
\fBADMINISTRATIVE\ ARRANGEMENTS\fR 
.ce 0
.sp 1P
.sp 2P
.LP
\fBRecommendation\ X.180\fR 
.RT
.sp 2P
.ce 1000
\fBADMINISTRATIVE\ ARRANGEMENTS\ FOR\ INTERNATIONAL\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Rec.\ X.180''
.OF '''Fascicle\ VIII.3\ \(em\ Rec.\ X.180	%'
.ce 0
.sp 1P
.ce 1000
\fBCLOSED\ USER\ GROUPS\ (CUGs)\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Geneva, 1980; amended at Melbourne, 1988)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIbearing in mind\fR 
.sp 9p
.RT
.PP
(a)
the introduction of international CUGs in public
networks that provide packet\(hyswitched and circuit\(hyswitched data transmission 
services;
.PP
(b)
the need to standardize a scheme for international CUG   numbers;
.PP
(c)
the need to standardize administrative procedures for
allocation of international CUG numbers and the establishment of international 
CUGs, 
.sp 2P
.LP
\fIunanimously recommends the following\fR 
.sp 1P
.RT
.PP
\fB1\fR One subscriber, hereafter called the \*Qresponsible
subscriber\*U, shall clearly be allocated the responsibility for all
organizational matters relating to an international CUG. The responsible
subscriber shall be nominated by the subscribers intending to form an
international CUG (see Note\ 1).
.sp 9p
.RT
.PP
\fB2\fR The Administration of the country housing this \*Qresponsible
subscriber\*U (hereafter called the \*Qcoordinating Administration\*U) 
shall act as the controlling and coordinating Administration for that CUG 
and shall carry 
out the discussions with the responsible subscriber about changes to the 
CUG. The coordinating Administration shall also be responsible for allocating 
the 
international CUG number (ICN) and for issuing the necessary information to
other Administrations involved in the CUG.
.sp 9p
.RT
.LP
.PP
\fB3\fR If the public network is a data network, the DNIC or DCC used for 
the construction of the ICN would be one proper to the coordinating 
Administration. If the public network is ISDN, the INIC (see Note\ 5) would 
be used for the construction of the ICN. If the responsible subscriber 
changes his country of residence, the ICN shall be changed in accordance 
with the DNIC, 
DCC or INIC of the new coordinating Administration.
.sp 9p
.RT
.PP
\fB4\fR The ICN allocated by the coordinating Administration shall be
retained for the period of existence of the international CUG even if the
location of members of the CUG changes, as long as the responsible subscriber 
is located within the area of the coordinating Administration. 
.bp
.sp 9p
.RT
.PP
\fB5\fR The ICN will be represented by two decimal numbers A/B, where A 
is the DNIC, DCC (plus one digit) or INIC in accordance with \(sc\ 3 above, 
and\ B is a 1\(hy5\ digit number (see Note\ 2). 
.sp 9p
.RT
.PP
\fB6\fR In order to allow efficient conversion of CUG information, where 
required, for international CUG calls, restrictions on allocation of the 
ICNs used by each coordinating Administration have to be applied. Provisionally 
the following guidelines should apply:
.sp 9p
.RT
.LP
	i)
	each coordinating Administration should allocate the
ICNs to international CUGs in sequence within a certain range of
the available total range of ICNs;
.LP
	ii)
	information should be sent regularly to the
Administrations concerned about the size and allocation of the
range used for ICNs in\ i) above;
.LP
	iii)
	the size of the range used should not be bigger than
necessary for the operation of the network.
.PP
\fB7\fR 
The following procedures should apply for the interchange of information 
between Administrations and subscribers of an international CUG. 
Where a subscriber belongs to more than one international CUG, the
procedures in this Recommendation must be applied separately for each
international CUG.
.sp 9p
.RT
.PP
7.1
A subscriber applying for membership of an international
CUG shall apply to his own Administration using standard application
procedures. He should supply full details of the responsible subscriber (see
Note\ 3).
.sp 9p
.RT
.PP
7.2
The Administration receiving the request should pass details in a standard 
format to the coordinating Administration as indicated in Annex\ A. 
.PP
7.3
The coordinating Administration will then verify with the
responsible subscriber whether the application can be permitted and, if
acceptable, will inform the applying subscriber's Administration of the ICN
allocated for that particular CUG.
.PP
7.4
The Administration of the applying subscriber shall inform the
coordinating Administration when the applying subscriber is connected.
.PP
7.5
The existing member Administrations of an international CUG shall be informed 
by the coordinating Administration when a subscriber of a new 
Administration has become a member of that CUG.
.PP
7.6
Changes in membership of an international CUG or cessation of a
CUG shall similarly be arranged between the responsible subscriber and the
coordinating Administration following individual applications from the
members of the CUG concerned.
.PP
7.7
The coordinating Administration shall, on request from the
responsible subscriber or one of the member Administrations of an
international CUG, supply information (print out) of all subscribers in that
particular CUG. The approval of the responsible subscriber is needed in the
latter case (see Note\ 4).
.PP
\fB8\fR The fact that the applying subscriber may be a member of
other CUGs or may wish to have outgoing or incoming access in addition 
to the CUG facility is of no relevance to the administrative procedures 
contained in this Recommendation. 
.sp 9p
.RT
.PP
\fINote\ 1\fR \ \(em\ It is assumed that in a CUG of an international
organization the headquarters branch probably will be the responsible
subscriber.
.PP
\fINote\ 2\fR \ \(em\ According to Recommendation X.300, the value B should
not be greater than 
2\u1\d\u6\d\ \(em\ 1\ =\ 65\|535.
.PP
\fINote\ 3\fR \ \(em\ To simplify the administrative arrangements, the 
procedures in \(sc\(sc\ 6.1 and\ 6.2 should be followed also in the case 
where the applying 
subscriber is a branch of an international organization and another branch 
of that organization is the responsible subscriber. 
.PP
\fINote\ 4\fR \ \(em\ Legal, or other, considerations may preclude some
coordinating Administrations from supplying such information at the request
of other member Administrations of an international CUG.
.PP
\fINote\ 5\fR \ \(em\ For ISDN identification, a four\(hydigit field ISDN 
Network 
Identification Code (INIC) is used. INIC consists of 0\ +\ E.164 country
code\ +\ national network digit(s). In order to identify additional ISDNs, 
some countries may also use 9\ +\ E.164 country code\ +\ national network 
digit(s). 
Alternative ways of ISDN network identification are for further
study.
.bp
.RT
.ce 1000
ANNEX\ A
.ce 0
.ce 1000
(to Recommendation X.180)
.sp 9p
.RT
.ce 0
.PP
The format and information to be passed to the coordinating
Administration following an application from a subscriber to join or cease
membership of an international closed user group is as follows:
.sp 1P
.RT
.PP
1
Application to join/cease membership of an international closed user group 
(CUG) on a public network has been received from: 
.sp 9p
.RT
.LP
	Firm
.LP
Address
.LP
Country
.LP
Public Network No.
.LP
Date of application
.LP
.PP
2
The responsible subscriber for this international CUG is:
.sp 9p
.RT
.LP
	Firm
.LP
Address
.LP
Public Network No.
.PP
3
The responsible subscriber's international CUG number (ICN)
.sp 9p
.RT
.PP
4
The applying subscriber requires the following facility (if
any):
.sp 9p
.RT
.LP
	\(em
	incoming calls barred within the CUG,
.LP
	\(em
	outgoing calls barred within the CUG.
.sp 2P
.LP
\fBRecommendation\ X.181\fR 
.RT
.sp 2P
.ce 1000
\fBADMINISTRATIVE\ ARRANGEMENTS\ FOR\ THE\ PROVISION\ OF\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ X.181''
.OF '''Fascicle\ VIII.3\ \(em\ X.181	%'
.ce 0
.sp 1P
.ce 1000
\fBINTERNATIONAL\ PERMANENT\ VIRTUAL\ CIRCUITS\ (PVCs)\fR 
.ce 0
.sp 1P
.ce 1000
\fI(Malaga\(hyTorremolinos, 1984; amended at Melbourne, 1988)\fR 
.sp 9p
.RT
.ce 0
.sp 1P
.sp 2P
.LP
	The\ CCITT,
.sp 1P
.RT
.sp 1P
.LP
\fIconsidering\fR 
.sp 9p
.RT
.PP
(a)
that the permanent virtual circuit service is listed in  Recommendation\ X.2;
.PP
(b)
that the permanent virtual circuit service may
not be available for all international connections and may not be available 
for the maritime mobile services (as noted in Recommendation\ X.2); 
.PP
(c)
that the international application of the permanent
virtual circuit service depends on bilateral agreement (as noted in
Recommendation\ X.2);
.LP
.PP
(d)
that Recommendation\ X.25 defines the DTE/DCE interface characteristics 
and Recommendation\ X.75 defines the procedures for 
international circuits between two STEs;
.PP
(e)
that there is a need to standardize administrative
procedures for the exchange of information characterizing the international
permanent virtual circuit among Administrations concerned, in order to
establish the international permanent virtual circuit,
.bp
.sp 2P
.LP
\fIunanimously recommends the following\fR 
.sp 1P
.RT
.PP
\fB1\fR 
One of the two subscribers to be connected by the
international PVC (hereafter called the \*Qresponsible subscriber\*U) shall 
clearly be allocated the responsibility for all organizational matters 
relating to an international PVC. The responsible subscriber shall be nominated 
by the 
subscribers to be connected by the international PVC (see Note\ 1).
.sp 9p
.RT
.PP
\fB2\fR 
The Administration of country housing this \*Qresponsible
subscriber\*U (hereafter called the \*Qsource Administration\*U) shall 
act as the 
controlling and coordinating Administration for that international PVC and
shall carry out the discussions with the responsible subscriber about any
changes to the international PVC.
.sp 9p
.RT
.LP
.PP
\fB3\fR 
The source Administration will normally gather information
required for charging and accounting for the international PVC (see Note\ 2).
.sp 9p
.RT
.PP
\fB4\fR 
The exchange of information for the provision of
international PVCs will be as follows:
.sp 9p
.RT
.PP
4.1
Source Administration and destination Administration (the
Administration housing the non\(hyresponsible subscriber) will need to exchange
information for the provision of the international PVC. This information 
should include: 
.LP
	a)
	international numbers of both subscriber DTEs,
.LP
	b)
	throughput class (both directions),
.LP
	c)
	name of the international PVC (see Note\ 3),
.LP
	d)
	proposal on routing,
.LP
	e)
	quality of service parameters (see Note\ 4),
.LP
	f
)
	service inauguration date and lifetime of the
international PVC.
.LP
.PP
4.2
If transit networks must be involved, the route
should be agreed on among Administrations involved. For the efficiency of
negotiation among Administrations, the source Administration may initiate 
the negotiation with its adjacent Administration after which negotiation 
between 
subsequent Administrations follows, until the destination Administration has
been reached. The information described in \(sc\ 4.1 should be conveyed to each
transit Administration, and the route should be determined satisfying the
requested throughput classes and quality of service (see Note\ 4).
.PP
4.3
Between adjacent Administrations, information to be exchanged
should include the following items in addition to the information described 
in \(sc\ 4.1: 
.LP
	a)
	the identity of STE X/Y interface,
.LP
	b)
	logical channel group number and logical channel
number,
.LP
	c)
	window size (both directions),
.LP
	d)
	packet size (both directions).
.LP
.PP
\fB5\fR 
The following procedures should apply for the interchange of
information between Administrations and subscribers of an international PVC.
Where a subscriber has subscribed to more than one international PVC, the
procedures in this Recommendation must be applied separately for each
international PVC.
.sp 9p
.RT
.PP
5.1
A subscriber applying for the provision of an international PVC
shall apply to his own Administration using standard application procedures. 
He should supply full details of the responsible subscriber. 
.PP
5.2
The Administration should, in case the request did not come
from the responsible subscriber, pass details in a standard format to the
source Administration as indicated in Annex\ A.
.PP
5.3
The source Administration will then verify with the responsible
subscriber whether the application can be permitted.
.PP
5.4
The source Administration will then negotiate with the destination Administration 
and possibly transit Administrations whether the application can be permitted, 
taking into account \(sc\ 4. 
.PP
5.5
If the conditions in \(sc\(sc\ 5.3 and 5.4 are accepted, the source
Administration will agree with the subscriber on the logical channel group
number and logical channel number to which the international PVC will be
connected. The destination Administration will do so with the other
subscriber.
.PP
5.6
The source Administration will inform both subscribers
involved when the international PVC is estab
lished.
.bp
.PP
5.7
If, during the lifetime of the international PVC, rerouting of
the international PVC is necessary, the responsible subscriber will be 
informed by the source Administration of any changes of either charging 
or quality of 
service of the international PVC (see Note\ 5).
.PP
\fINote\ 1\fR \ \(em\ It is assumed that the responsible subscriber is 
one of the two subscribers to be connected by the international PVC. 
.PP
\fINote\ 2\fR \ \(em\ Other arrangements are possible on a bilateral basis.
.PP
\fINote\ 3\fR \ \(em\ A name of an international PVC should be unique among 
the Administrations involved, (e.g.,\ the specification of the international 
number, the logical channel group number and the logical channel number to
which the international PVC is connected for both subscribers).
.PP
\fINote\ 4\fR \ \(em\ The parameters concerning quality of service are for
further study.
.PP
\fINote\ 5\fR \ \(em\ The impact of a possible inclusion of an automatic
(re)establishment procedure is for further study.
\v'2P'
.RT
.ce 1000
ANNEX\ A
.ce 0
.ce 1000
(to Recommendation X.181)
.sp 9p
.RT
.ce 0
.PP
The format and information to be passed to the source
Administration following an application from a subscriber for the provision 
of an international PVC is as follows: 
.sp 1P
.RT
.PP
1
Application for the establishment of an international permanent
virtual circuit (PVC) via several public networks has been received
from:
.sp 9p
.RT
.LP
	Firm
.LP
Address
.LP
Country
.LP
International number
.LP
Date of application
.PP
2
The applicant as indicated in 1) above requests to be connected
via an international PVC with:
.sp 9p
.RT
.LP
	Firm
.LP
Address
.LP
Country
.LP
International number
.PP
3
The responsible subscriber's international data number:
.sp 9p
.RT
.PP
4
The following is requested:
.sp 9p
.RT
.LP
	\(em
	throughput class,
.LP
	\(em
	service inauguration date,
.LP
	\(em
	requested lifetime of the international PVC.
.LP
.rs
.sp 09P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.LP
\fBMONTAGE:\ \fR PAGE PAIRE = PAGE BLANCHE
.sp 1P
.RT
.LP
.bp
.sp 1P
.ce 1000
\v'12P'
\s12PART\ II
\v'4P'
.RT
.ce 0
.sp 1P
.ce 1000
\fBSUPPLEMENT\ TO\ RECOMMENDATION\ X.135\fR 
.EF '%	 \ \ \ ^''
.OF ''' \ \ \ ^	%'
.ce 0
.sp 1P
.LP
.rs
.sp 31P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.LP
\fBMONTAGE:\ \fR PAGE ... = PAGE BLANCHE
.sp 1P
.RT
.LP
.bp
.sp 1P
.ce 1000
\fBSupplement No. 1\fR 
.RT
.sp 2P
.ce 0
.sp 1P
.ce 1000
\fBSOME\ TEST\ RESULTS\ FROM\ SPECIFIC\ NATIONAL\fR 
.EF '%	Fascicle\ VIII.3\ \(em\ Suppl.\ No.\ 1''
.OF '''Fascicle\ VIII.3\ \(em\ Suppl.\ No.\ 1	%'
.ce 0
.ce 1000
\fBAND\ INTERNATIONAL\ PORTIONS\fR 
.ce 0
.sp 1P
.ce 1000
(referenced in Recommendation X.135)
.sp 9p
.RT
.ce 0
.sp 1P
.PP
This supplement presents test results and is intended for
illustrative purposes only. It contains results for national\ A and national\ 
B portions. The results were measured in the DATEX\(hyP network, which 
is operated by the Deutsche Bundespost in the Federal Republic of Germany. 
.sp 1P
.RT
.PP
Since these figures apply to one network under a specific network traffic 
load at a specific time, they cannot be taken in any way to be 
presentative of the current or likely performance of either other networks 
of this same network at a different point of time. They are included for 
the 
sole purpose of summarizing one experiment in which the network performance 
was better than that defined in Recommendation\ X.135. 
.PP
The above implies that many factors, including a particular set of
equipment types, a specific configuration, distribution of network traffic
loading, network topology, and network\(hyspecific dimensioning rules, 
impact the values obtained. 
.RT
.sp 2P
.LP
\fB1\fR 	\fBNational A portion delay and throughput values\fR 
.sp 1P
.RT
.PP
Table 1 presents call set\(hyup delay, data packet transfer delay,
throughput capacity, and clear indication delay values measured in a DATEX\(hyP
configuration selected to represent this National\ A portion of an international 
virtual connection. The measurements were taken during the busy hour on 
a 
representative set of connections. These results demonstrate that the delay 
and throughput performance provided in the National\ A portion can be much 
better 
than is indicated by the worst\(hycase values specified in
Recommendation\ X.135.
.RT
.sp 2P
.LP
\fB2\fR 	\fBNational B portion delay and throughput values\fR 
.sp 1P
.RT
.PP
Table 2 presents call set\(hyup delay, data packet transfer delay,
throughput capacity, and clear indication delay values measured in a DATEX\(hyP
configuration selected to represent the National\ B portion of an international 
virtual connection. The measured configuration included a 128\ kbit/s satellite 
circuit. The measurements were taken during the busy hour. These results 
demonstrate that the delay and throughput performance provided in the
National\ B portion can be much better than is indicated by the worst\(hycase
values specified in Recommendation\ X.135.
.RT
.LP
.rs
.sp 12P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.ce
\fBH.T. [T17.135]\fR 
.ce
TABLE\ 1
.ce
\fBMeasured national A portion delay and throughput capacity
.ce
values\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(84p) | cw(36p) sw(36p) sw(36p) sw(36p) , ^  | c | c | c | c.
Statistic	Measured national A value
	Minimum	Mean	95th Percentile	Maximum
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Call set\(hyup delay (ms)	388	\ 450	517	588
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
T{
Data packet transfer delay (ms)
T}	147	\ 169	193	203
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Throughput capacity (bit/s)	\(em	6287	\(em	\(em
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Clear indication delay (ms)	\ 85	\ 107	142	T{
180
\fINote\ 1\fR
\ \(em\ The measurements summarized in this table were conducted in
January\ 1987. All reported values are based on measurements of at least
5\ different 3\(hyhop paths within the DATEX\(hyP network. Each reported delay value is an average of at least 100\ indvidual measurements, including at least
20\ measurements on each path. The reported throughput capacity value is an
average of 40\ individual measurements, each involving the transfer of at least 450\ packets.
.parag
\fINote\ 2\fR
\ \(em\ The data packet transfer delay and throughput capacity values were measured using data packets having a 128\(hyoctet user data field. In the
throughput capacity measurements, the signalling rate on the access circuit
sections was 9600\ bit/s; the packet layer window size on the access circuit
sections was\ 2; and the network internal packet layer window size was\ 4. (The network internal window is a network specific throughput class implementation in which higher negotiated throughput classes result in larger network internal window.)
.parag
\fINote\ 3\fR
\ \(em\ The clear indication delay values were estimated by measuring the
time between transmission of a clear indication packet and receipt of the
corresponding clear confirmation packet at the clearing DSE, and dividing
the result by\ 2. Clear confirmation has end\(hyto\(hyend significance in the DATEX\(hyP network.
.parag
\fINote\ 4\fR
\ \(em\ The reported delay values do not include delays in the access
circuit sections or the DTEs.
.parag
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau 1 [T17.135], p. 28\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.rs
.sp 18P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.ce
\fBH.T. [T18.135]\fR 
.ce
TABLE\ 2
.ce
\fBMeasured national B portion delay and throughput capacity\fR 
.ce
\fBvalues\fR 
.ps 9
.vs 11
.nr VS 11
.nr PS 9
.TS
center box;
cw(84p) | cw(36p) sw(36p) sw(42p) sw(30p) , ^  | c | c | c | c.
Statistic	Measured nation B values
	Minimum	Mean	95th percentile	Maximum
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Call set\(hyup delay (ms)	1040	1089	1126	1197
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
T{
Data packet transfer delay (ms)
T}	\ 471	\ 495	\ 531	\ 537
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Throughput capacity (bit/s)				
.T&
lw(60p) | cw(24p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) , ^  | c | c | c | c | c 
^  | c | c | c | c | c.
Network internal window size	\ 4	\(em	4127	\(em	\(em
	\ 7	\(em	5350	\(em	\(em	15	\(em	8595	\(em	\(em
_
.T&
lw(84p) | cw(36p) | cw(36p) | cw(36p) | cw(36p) .
Clear indication delay (ms)	\ 406	\ 432	\ 455	T{
\ 468
\fINote\ 1\fR
\ \(em\ The measurements summarized in this table were conducted in
January\ 1987. All reported values are based on measurements of at least
5\ different 3\(hyhop paths (including 1\ satellite\(hyhop) within the DATEX\(hyP network. Each reported delay value is an average of at least 100\ individual
measurements, including at least 20\ measurements on each path.
Each reported throughput capacity value is an average of at least 40\ individual measurements, each involving the transfer of at least 450\ packets.
.parag
\fINote\ 2\fR
\ \(em\ The data packet transfer delay values were measured using data
packets having a 128\(hyoctet user data field.
In each measurement, the signalling rate on the access circuit sections was
9600\ bit/s and the packet layer window size on the access circuit section
was\ 2.
.parag
\fINote\ 3\fR
\ \(em\ The clear indication delay values were estimated by measuring the
time between transmission of a clear indication packet and receipt of the
corresponding clear confirmation packet at the clearing DSE, and dividing the result by\ 2. Clear confirmation has end\(hyto\(hyend significance in the DATEX\(hyP
network.
.parag
\fINote\ 4\fR
\ \(em\ The reported delay values do not include delays in the access
circuit sections or the\ DTEs.
.parag
\fINote\ 5\fR
\ \(em\ The measured values demonstrate that the packet layer network
internal window size can strongly influence the throughput capacity of virtual connection portions that contain a satellite circuit.
.parag
T}
_
.TE
.nr PS 9
.RT
.ad r
\fBTableau 2 [T18.135], p. 29\fR 
.sp 1P
.RT
.ad b
.RT
.LP
.rs
.sp 10P
.ad r
BLANC
.ad b
.RT
.LP
.bp
.LP
\fBMONTAGE:\ \ \ \fR PAGE PAIRE = PAGE BLANCHE
.sp 1P
.RT
.LP
.bp