Subject: RE: hot water and sanitizer
Date: Thu, 20 Dec 2001 11:06:25 -0600
MIME-Version: 1.0
X-Mailer: Internet Mail Service (5.5.2653.19)
Content-Type: text/plain;
	charset="iso-8859-1"

if you want a long term solution
may i suggest installation of an _insulated_ line that runs from HWH to
sterilizer directly,
bypassing the house trunk and
giving equivalent pressure to both sterilizer and house main trunk.
such a direct feed could have a booster placed on it as well,
with a switch in the kitchen.

thoughts?

Noah G. Greenberg
Architect

DLR Group Seattle
206/461-6000


> -----Original Message-----
> From: scs@eskimo.com [mailto:scs@eskimo.com]
> Sent: Thursday, December 20, 2001 8:02 AM
> To: in-house-pikans@mit.edu
> Cc: nutso-flaming-pikans@mit.edu; scs@eskimo.com
> Subject: Re: hot water and sanitizer
> 
> 
> William F MacFarlane wrote:
> >	A bad thing is that the sanitizer, clever little devil 
> that it is,
> > also knows to take water from the hot water supply.  
> Because the hot water
> > supply does not supply at the moment this is a bit of a conundrum.
> >	What YOU must do, as a good dish-washing pikan is fill the
> > sanitizer up with cold water from the sink to get it started...
> 
> There's a super secret, alternative solution.
> 
> Lo these many years ago, in 1981 or so, when a previous water
> heater gave out and I replaced it, I thought this would be a
> useful problem to solve.  (It turns out I was wrong, but read on.)
> I installed a bypass valve above the water heater which enables
> you to divert cold water into the hot water pipes, while leaving
> the water heater completely isolated (i.e. while it's being
> replaced).  This valve is intended to be opened only during those
> occasions when the water heater is broken, and only in order to
> get water to the sterilizer which it can then try to heat.
> 
> Now, in fact, it sounds like cold water is so non-useful in the
> sterilizer that filling it some other way (i.e. with water boiled
> on the stove) is a better idea anyway.  And, as far as I know, in
> 20 years the only time that bypass valve has ever been opened was
> by a housemanager whose name I won't mention (but whose initials
> are Jenifer Tidwell) who tried to fix a hot-water-not-hot-enough
> problem by opening it, thus making the problem even worse (i.e. by
> mixing cold water in with the hot).  So, in retrospect, although
> I still give myself an A+ for forward thinking, I have to concede
> that the bypass valve gets at best a C- for practicality.
> 
> (Still, it might be fun to open it, now that its time has come,
> and to enable the sterilizer to do its trickle-fill thing after
> each load.  OTOH, hopefully by tonight when it's time to do
> dishes again, the water heater'll be replaced anyway...)
> 
> scs '83
> 